Inspection 341728509 OPENED AUG 26, 2016Closed
410 Knickerbocker Ave, Brooklyn, NY 11237 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Since 2016, OSHA inspectors have visited Bijoy Construction Corp. in New York 2 times.
The most recent inspection opened on Aug 26, 2016 to follow up on an earlier case, in Brooklyn.
In all, OSHA issued 4 citation items: 4 serious.
The penalties, $8,800 in total, stand where OSHA first set them.
The rule cited most here is 1926.451 (scaffolds, general requirements), 2 times.
Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Bijoy Construction Corp. averages $8,800 across 1 cited inspection.
New York · latest 90 days of OSHA records
350employers cited
Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in New York
Checking a subcontractor, a client or your own company? Watch Bijoy Construction Corp. and get notified the morning OSHA posts a new citation for it.
Watch this company410 Knickerbocker Ave, Brooklyn, NY 11237 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
410 Knickerbocker Ave, Brooklyn, NY 11237 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements |
Serious | $2,800 | $2,800 | Mar 24, 2016 | Final |
| Citation 1, item 2 29 CFR 1926.451(h)(2)(ii) · Scaffolds, general requirements |
Serious | $2,000 | $2,000 | Mar 24, 2016 | Final |
| Citation 1, item 3 29 CFR 1926.502(i)(3) · Fall protection systems |
Serious | $2,000 | $2,000 | Mar 24, 2016 | Final |
| Citation 1, item 4 29 CFR 1926.1052(c)(12) · Stairways in construction |
Serious | $2,000 | $2,000 | Mar 24, 2016 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.1052(c)(12)
(12) Unprotected sides and edges of stairway landings shall be provided with guardrail systems. Guardrail system criteria are contained in subpart M of this part.
29 CFR 1926.451(g)(4)(i)
(i) Guardrail systems shall be installed along all open sides and ends of platforms. Guardrail systems shall be installed before the scaffold is released for use by employees other than erection/dismantling crews.
29 CFR 1926.451(h)(2)(ii)
(ii) A toeboard shall be erected along the edge of platforms more than 10 feet (3.1 m) above lower levels for a distance sufficient to protect employees below, except on float (ship) scaffolds where an edging of 3/4 × 1 1/2 inch (2 × 4 cm) wood or equivalent may be used in lieu of toeboards;
Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.