Black Electric, Inc: OSHA inspections and violations

Grinnell, Iowa · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

1inspections
4citation items
$2,025current penalties
Jun 26, 2017last inspection

OSHA inspectors have visited Black Electric, Inc in Iowa one time.

It opened on Jun 26, 2017, in Grinnell.

In all, OSHA issued 4 citation items: 4 serious.

The proposed penalties came to $4,050; today they stand at $2,025, 50% less.

The rule cited most here is 1926.405 (job-site wiring), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Black Electric, Inc averages $2,025 across 1 cited inspection.

Black Electric, Inc: OSHA citation items per year, 2017 to 2017
Citation items per year, by inspection date.

Iowa · latest 90 days of OSHA records

64employers cited

Get notified the morning OSHA posts each new citation in Iowa: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Iowa

Checking a subcontractor, a client or your own company? Watch Black Electric, Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342429347 OPENED JUN 26, 2017Closed

Unprogrammed other · Complete · Safety · 2 employees at the site · Closed Sep 26, 2017

925 Park St., Grinnell, IA 50112 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.403(b)(2) · Electrical equipment on job sites
Serious$750$375Jul 18, 2017Final
Citation 1, item 2
29 CFR 1926.404(b)(1)(i) · Ground-fault protection on job sites
Serious$1,050$525Jul 18, 2017Final
Citation 1, item 3
29 CFR 1926.405(b)(1) · Job-site wiring
Serious$750$375Jul 18, 2017Final
Citation 1, item 4
29 CFR 1926.405(d) · Job-site wiring
Serious$1,500$750Jul 18, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.403(b)(2)

(2) Installation and use. Listed, labeled, or certified equipment shall be installed and used in accordance with instructions included in the listing, labeling, or certification.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(i)

(b) Branch circuits—(1) Ground-fault protection—(i) General. The employer shall use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(b)(1)

(b) Cabinets, boxes, and fittings—(1) Conductors entering boxes, cabinets, or fittings. Conductors entering boxes, cabinets, or fittings shall be protected from abrasion, and openings through which conductors enter shall be effectively closed. Unused openings in cabinets, boxes, and fittings shall also be effectively closed.

Other electrical contractors and other wiring installation contractors employers in Iowa

Alert subscribers get notified of each newly cited employer in Iowa the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.