OSHA SearchOSHA records by employer

Blenheim Fire Company #1: OSHA inspections and violations

Blackwood, New Jersey · Fire Protection · NAICS 922160

4inspections
11citation items
$13,000current penalties
Oct 4, 2016last inspection

Since 2016, OSHA inspectors have visited Blenheim Fire Company #1 in New Jersey 4 times.

The most recent inspection opened on Oct 4, 2016 to follow up on an earlier case, in Blackwood.

In all, OSHA issued 11 citation items: 6 serious and 5 other-than-serious.

The penalties, $13,000 in total, stand where OSHA first set them.

The rule cited most here is 1910.303 (electrical equipment, general requirements), 2 times.

Among public administration employers, the typical cited inspection since 2015 ends with a $0 penalty. Blenheim Fire Company #1 averages $6,500 across 2 cited inspections.

Blenheim Fire Company #1: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

New Jersey · latest 90 days of OSHA records

274employers cited

5 of them in the same industry

Get notified the morning OSHA posts each new citation in New Jersey: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New Jersey

Checking a subcontractor, a client or your own company? Watch Blenheim Fire Company #1 and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341812105 OPENED OCT 4, 2016Closed

Follow-up · Partial · Safety · Local government · 18 employees at the site · Closed Oct 4, 2016

34 Almonesson Road, Blackwood, NJ 08012 · Fire Protection · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 341812238 OPENED OCT 4, 2016Closed

Follow-up · Partial · Safety · Local government · 18 employees at the site · Closed Oct 4, 2016

34 Almonesson Road, Blackwood, NJ 08012 · Fire Protection · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 341487981 OPENED MAY 19, 2016Closed

Planned · Complete · Safety · Local government · 18 employees at the site · Closed Oct 4, 2016

34 Almonesson Road, Blackwood, NJ 08012 · Fire Protection · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR N.J.A.C. 12:100-10.6(A)(1)
Serious$1,600$1,600May 27, 2016Final

Inspection 341488021 OPENED MAY 19, 2016Closed

Planned · Complete · Safety · Local government · 18 employees at the site · Closed Oct 4, 2016

34 Almonesson Road, Blackwood, NJ 08012 · Fire Protection · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.132(d)(1) · Personal protective equipment, general requirements
Serious$2,000$2,000May 27, 2016Final
Citation 1, item 2
29 CFR 1910.243(b)(2) · Guarding of portable powered tools
Serious$1,600$1,600May 27, 2016Final
Citation 1, item 3
29 CFR 1910.303(b)(7)(iv) · Electrical equipment, general requirements
Serious$1,600$1,600May 27, 2016Final
Citation 1, item 4
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$1,600$1,600May 27, 2016Final
Citation 1, item 5
29 CFR 1910.305(j)(2)(iv) · Electrical wiring methods
Serious$1,600$1,600May 27, 2016Final
Citation 2, item 1
29 CFR 1910.39(b) · Fire prevention plans
Other-than-serious$600$600May 27, 2016Final
Citation 2, item 2
29 CFR N.J.A.C. 12:100-7.7(A)
Other-than-serious$600$600May 27, 2016Final
Citation 2, item 3
29 CFR N.J.A.C. 12:100-7.8(A) (OPTION
Other-than-serious$600$600May 27, 2016Final
Citation 2, item 4
29 CFR N.J.A.C. 12:100-10.3(C)(5)
Other-than-serious$600$600May 27, 2016Final
Citation 2, item 5
29 CFR N.J.A.C. 12:100-10.16(B) (OPT
Other-than-serious$600$600May 27, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.132(d)(1)

(d) Hazard assessment and equipment selection. (1) The employer shall assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE). If such hazards are present, or likely to be present, the employer shall:

29 CFR 1910.243 · Guarding of portable powered tools

29 CFR 1910.243(b)(2)

(2) Airhose. Hose and hose connections used for conducting compressed air to utilization equipment shall be designed for the pressure and service to which they are subjected.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(b)(7)(iv)

(iv) There shall be no damaged parts that may adversely affect safe operation or mechanical strength of the equipment, such as parts that are broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating.

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.39 · Fire prevention plans

Other fire protection employers in New Jersey

Alert subscribers get notified of each newly cited employer in New Jersey the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.