Blok Group, Inc.: OSHA inspections and violations

Piscataway, New Jersey · Roofing Contractors · NAICS 238160

2inspections
7citation items
$11,217current penalties
Dec 11, 2018last inspection

Since 2016, OSHA inspectors have visited Blok Group, Inc. in New Jersey 2 times.

The most recent inspection opened on Dec 11, 2018 as a planned inspection, in Hackensack.

In all, OSHA issued 7 citation items: 7 serious.

The proposed penalties came to $19,428; today they stand at $11,217, 42% less.

The rule cited most here is 1926.502 (fall protection systems), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Blok Group, Inc. averages $5,608 across 2 cited inspections.

Blok Group, Inc.: OSHA citation items per year, 2016 to 2018
Citation items per year, by inspection date.

New Jersey · latest 90 days of OSHA records

269employers cited

39 of them in the same industry

Get notified the morning OSHA posts each new citation in New Jersey: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New Jersey

Checking a subcontractor, a client or your own company? Watch Blok Group, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343657482 OPENED DEC 11, 2018Closed

Planned · Partial · Safety · 2 employees at the site · Closed Nov 4, 2022

202 Essex Street, Hackensack, NJ 07601 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$4,376$2,626Feb 26, 2019Final
Citation 1, item 2
29 CFR 1926.452(j)(2) · Rules for each type of scaffold
Serious$3,126$1,876Feb 26, 2019Final
Citation 1, item 3
29 CFR 1926.501(b)(11) · Fall protection in construction
Serious$3,126$1,876Feb 26, 2019Final

Inspection 341233625 OPENED FEB 8, 2016Closed

Planned · Partial · Safety · 8 employees at the site · Closed Jul 26, 2017

300 South Randolphville Road, Piscataway, NJ 08854 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$2,800$1,540Apr 20, 2016Final
Citation 1, item 2
29 CFR 1926.502(f)(1)(iii) · Fall protection systems
Serious$2,000$1,100Apr 20, 2016Final
Citation 1, item 3
29 CFR 1926.502(f)(2)(ii) · Fall protection systems
Serious$1,600$880Apr 20, 2016Final
Citation 1, item 4
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$2,400$1,320Apr 20, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(g)(1)

(g) Fall protection. (1) Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1) (i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.452(j)(2)

(2) Poles shall be secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. When the pump jack has to pass bracing already installed, an additional brace shall be installed approximately 4 feet (1.2 m) above the brace to be passed, and shall be left in place until the pump jack has been moved and the original brace reinstalled.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.502 · Fall protection systems

Other roofing contractors employers in New Jersey

Alert subscribers get notified of each newly cited employer in New Jersey the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.