OSHA SearchOSHA records by employer

Blue Cost Construction, Inc.: OSHA inspections and violations

Lauderdale By The Sea, Florida · Poured Concrete Foundation and Structure Contractors · NAICS 238110

4inspections
10citation items
$46,136current penalties
Aug 29, 2024last inspection

OSHA has inspected Blue Cost Construction, Inc. 4 times in Florida since 2015.

The latest one began on Aug 29, 2024 on a referral, in Boca Raton.

Those inspections ended with 10 citation items: 8 serious and 2 other-than-serious.

Penalties were first proposed at $51,357 and now stand at $46,136, 10% lower after settlements or reviews.

Ladders in construction comes up most often in these citations: 4 items under 1926.1053.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Blue Cost Construction, Inc. averages $11,534 (4 cited inspections).

Blue Cost Construction, Inc.: OSHA citation items per year, 2015 to 2024
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

321employers cited

7 of them in the same industry

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch Blue Cost Construction, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347730517 OPENED AUG 29, 2024Closed

Referral · Partial · Safety · 54 employees at the site · Closed Jun 25, 2025

2800 S Ocean Drive, Boca Raton, FL 33432 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$12,768$12,768Jan 27, 2025Final
Citation 1, item 2a
29 CFR 1926.1052(c)(1)(ii) · Stairways in construction
Serious$12,768$12,768Jan 27, 2025Final
Citation 1, item 2b
29 CFR 1926.1052(c)(12) · Stairways in construction
Serious$0$0Jan 27, 2025Final
Citation 1, item 3a
29 CFR 1926.1053(b)(4) · Ladders in construction
Serious$12,768$12,768Jan 27, 2025Final
Citation 1, item 3b
29 CFR 1926.1053(b)(21) · Ladders in construction
Serious$0$0Jan 27, 2025Final

Inspection 345647846 OPENED NOV 19, 2021Closed

Complaint · Partial · Safety · 12 employees at the site · Closed Apr 19, 2023

2800 N Sr - A1a, Hutchinson Island, FL 34949 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$7,252$4,351May 5, 2022Final
Citation 1, item 2a
29 CFR 1926.1053(b)(15) · Ladders in construction
Serious$5,801$3,481May 5, 2022Final
Citation 1, item 2b
29 CFR 1926.1053(b)(16) · Ladders in construction
Serious$0$0May 5, 2022Final

Inspection 340370279 OPENED FEB 11, 2015Closed

Complaint · Partial · Health · 21 employees at the site · Closed May 11, 2015

4900 North Ocean Blvd., Lauderdale By The Sea, FL 33308 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(c)(2)(i) · Respiratory protection
Other-than-serious$0$0Apr 10, 2015Final

Inspection 340390871 OPENED FEB 11, 2015Closed

Complaint · Partial · Safety · 20 employees at the site · Closed Jul 7, 2015

4900 North Ocean Blvd, Lauderdale By The Sea, FL 33308 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(c) · Fall protection in construction
Other-than-serious$0$0Jun 5, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(c)(2)(i)

(i) An employer may provide respirators at the request of employees or permit employees to use their own respirators, if the employer determines that such respirator use will not in itself create a hazard. If the employer determines that any voluntary respirator use is permissible, the employer shall provide the respirator users with the information contained in appendix D to this section (“Information for Employees Using Respirators When Not Required Under the Standard”); and

29 CFR 1926.1052 · Stairways in construction

29 CFR 1926.1052(c)(1)(ii)

(ii) One stairrail system along each unprotected side or edge.

29 CFR 1926.1052(c)(12)

(12) Unprotected sides and edges of stairway landings shall be provided with guardrail systems. Guardrail system criteria are contained in subpart M of this part.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.501 · Fall protection in construction

Other poured concrete foundation and structure contractors employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.