BMD Construction: OSHA inspections and violations

De Witt, New York · Roofing Contractors · NAICS 238160

1inspections
4citation items
$1,000current penalties
Apr 12, 2017last inspection

OSHA inspectors have visited BMD Construction in New York one time.

It opened on Apr 12, 2017 after a complaint, in De Witt.

In all, OSHA issued 4 citation items: 4 serious.

The proposed penalties came to $6,519; today they stand at $1,000, 85% less.

The rule cited most here is 1926.404 (ground-fault protection on job sites), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,078 penalty. BMD Construction averages $1,000 across 1 cited inspection.

BMD Construction: OSHA citation items per year, 2017 to 2017
Citation items per year, by inspection date.

Want to know if OSHA cites BMD Construction again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 342246063 OPENED APR 12, 2017Closed

Complaint · Complete · Safety · 5 employees at the site · Closed Aug 25, 2022

101 Pelham Drive, De Witt, NY 13214 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.28(a) · Personal protective equipment
Serious$1,630$333Apr 21, 2017Final
Citation 1, item 2a
29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites
Serious$2,173$333Apr 21, 2017Final
Citation 1, item 2b
29 CFR 1926.404(f)(6) · Ground-fault protection on job sites
Serious$0$0Apr 21, 2017Final
Citation 1, item 3
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$2,716$333Apr 21, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.28 · Personal protective equipment

29 CFR 1926.28(a)

(a) The employer is responsible for requiring the wearing of appropriate personal protective equipment in all operations where there is an exposure to hazardous conditions or where this part indicates the need for using such equipment to reduce the hazards to the employees.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(ii)

(ii) Ground-fault circuit interrupters. All 120-volt, single-phase, 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, shall have approved ground-fault circuit interrupters for personnel protection. Receptacles on a two-wire, single-phase portable or vehicle-mounted generator rated not more than 5kW, where the circuit conductors of the generator are insulated from the generator frame and all other grounded surfaces, need not be protected with ground-fault circuit interrupters.

29 CFR 1926.404(f)(6)

(6) Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent and continuous.

29 CFR 1926.501 · Fall protection in construction