OSHA SearchOSHA records by employer

Boise Hunter Homes, LLC: OSHA inspections and violations

Meridian, Idaho · New Housing For-Sale Builders · NAICS 236117

3inspections
3citation items
$9,226current penalties
Jul 28, 2025last inspection

Since 2012, OSHA inspectors have visited Boise Hunter Homes, LLC in Idaho 3 times.

The most recent inspection opened on Jul 28, 2025 on a referral, in Eagle.

In all, OSHA issued 3 citation items: 3 serious.

The proposed penalties came to $13,277; today they stand at $9,226, 31% less.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Boise Hunter Homes, LLC averages $8,342 across 1 cited inspection.

Boise Hunter Homes, LLC also files yearly injury logs with OSHA, summarized below.

Boise Hunter Homes, LLC: OSHA citation items per year, 2012 to 2025
Citation items per year, by inspection date.

Idaho · latest 90 days of OSHA records

62employers cited

Get notified the morning OSHA posts each new citation in Idaho: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Idaho

Checking a subcontractor, a client or your own company? Watch Boise Hunter Homes, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348409996 OPENED JUL 28, 2025Closed

Referral · Partial · Safety · 64 employees at the site · Closed Nov 13, 2025

Dry Creek Ranch Subdivision On Or Near Diamond Lake Drive, Eagle, ID 83616 · New Housing For-Sale Builders · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$7,945$5,562Sep 29, 2025Final
Citation 1, item 2
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$3,972$2,780Sep 29, 2025Final

Inspection 339148892 OPENED JUN 14, 2013Closed

Planned · Partial · Safety · 25 employees at the site · Closed Jun 14, 2013

2565 Trailwood Dr, Boise, ID 83712 · New Housing For-Sale Builders · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 334577335 OPENED JUN 1, 2012Closed

Referral · Partial · Safety · 10 employees at the site · Closed Aug 14, 2012

5616 N. Morpheus, Meridian, ID 83642 · New Housing For-Sale Builders · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.405(d) · Job-site wiring
Serious$1,360$884Jun 26, 2012Final

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Eagle site logged 1 recordable injury or illness among about 70 workers: 1.7 per 100 full-time workers, against a median of 1.8 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Idaho Management Company, LLC
Eagle · 2025
70 101.71.8

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(d)

(d) Switchboards and panelboards. Switchboards that have any exposed live parts shall be located in permanently dry locations and accessible only to qualified persons. Panelboards shall be mounted in cabinets, cutout boxes, or enclosures designed for the purpose and shall be dead front. However, panelboards other than the dead front externally-operable type are permitted where accessible only to qualified persons. Exposed blades of knife switches shall be dead when open.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(13)

(13) Residential construction. Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of § 1926.502.

Other new housing for-sale builders employers in Idaho

Alert subscribers get notified of each newly cited employer in Idaho the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.