OSHA SearchOSHA records by employer

Bon L Manufacturing Company: OSHA inspections and violations

Newnan, Georgia · Alumina and Aluminum Production and Processing · NAICS 331316

6inspections
6citation items
$29,798current penalties
Jul 1, 2019last inspection

Since 2004, OSHA inspectors have visited Bon L Manufacturing Company in Georgia 6 times.

The most recent inspection opened on Jul 1, 2019 to follow up on an earlier case, in Newnan.

In all, OSHA issued 6 citation items: 5 serious and 1 other-than-serious.

The proposed penalties came to $41,811; today they stand at $29,798, 29% less.

The rule cited most here is 1910.147 (lockout/tagout), 2 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Bon L Manufacturing Company averages $23,558 across 1 cited inspection.

2 inspections on this page followed a fatal incident.

Bon L Manufacturing Company: OSHA citation items per year, 2004 to 2019
Citation items per year, by inspection date.

Georgia · latest 90 days of OSHA records

157employers cited

Get notified the morning OSHA posts each new citation in Georgia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Georgia

Checking a subcontractor, a client or your own company? Watch Bon L Manufacturing Company and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344141999 OPENED JUL 1, 2019Closed

Follow-up · Partial · Safety · 349 employees at the site · Closed Mar 2, 2020

25 Bonnell Street, Newnan, GA 30263 · Other Aluminum Rolling, Drawing, and Extruding · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 343082319 OPENED APR 11, 2018Closed

Fatality or catastrophe · Partial · Safety · 350 employees at the site · Closed Nov 7, 2018

25 Bonnell Street, Newnan, GA 30263 · Other Aluminum Rolling, Drawing, and Extruding · OSHA's record · Phone and website on Google Maps

Incident on Apr 11, 2018 (fatal): Employee is killed when struck by falling furnace door

At 12:00 p.m. on April 11, 2018, Employee #1 and a coworker were assigned to work on the Sow Preheater #1 furnace. They were to repair the rotary switch, the cable, and the door of the preheater. The employee raised the door via the control panel, to determine the clearance requirement of the door. The coworker stepped back to watch the height of the door and instructed the employee when to stop the upward travel of the door. Once the door was raised to the required height, the coworker marked the upper travel height using the JLG scissor lift that was on site. Once the door was stopped, the coworker turned away from the door to gather his tools. The employee left the control panel and walked under the door to obtain measurements for the headache bar. The supporting cable broke, causing the raised furnace door to fall, landing on the employee. Employee #1 was crushed and killed.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$12,934$9,700Oct 9, 2018Final
Citation 1, item 2
29 CFR 1910.147(c)(7)(i)(a) · Lockout/tagout
Serious$11,086$8,314Oct 9, 2018Final
Citation 1, item 3
29 CFR 1910.303(g)(2) · Electrical equipment, general requirements
Serious$7,391$5,543Oct 9, 2018Final

Inspection 341591758 OPENED JUN 29, 2016Closed

Referral · Partial · Health · 400 employees at the site · Closed Nov 21, 2016

25 Bonnell Street, Newnan, GA 30263 · Alumina and Aluminum Production and Processing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 337583819 OPENED NOV 28, 2012Closed

Planned · Partial · Health · 209 employees at the site · Closed Jun 7, 2013

25 Bonnell Street, Newnan, GA 30263 · Alumina and Aluminum Production and Processing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.1030(c)(1)(iv) · Bloodborne pathogens
Other-than-serious$0$0Mar 20, 2013Final

Inspection 337607824 OPENED NOV 28, 2012Closed

Complaint · Partial · Safety · 200 employees at the site · Closed May 1, 2013

25 Bonnell Street, Newnan, GA 30263 · Alumina and Aluminum Production and Processing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.22(b)(1) · General requirements
Serious$3,400$2,040Mar 20, 2013Final
Citation 1, item 2
29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts
Serious$7,000$4,200Mar 20, 2013Final

Inspection 307346957 OPENED JUN 17, 2004Closed

Accident · Partial · Safety · 3,200 employees at the site · Closed Jul 7, 2005

25 Bonnell Street, Newnan, GA 30263 · Alumina and Aluminum Production and Processing · OSHA's record · Phone and website on Google Maps

Incident on Jun 16, 2004 (fatal): Employee is caught in a press and dies

On June 16, 2004, Employee #1, a second shift maintenance worker, was assigned t o perform maintenance on the Number 3 Sutton Extrusion press. A coworker assigne d to the Number 3 press on the first shift had seen a leak under the shear openi ng. The coworker on the first shift did not take care of the leak as he was work ing on another problem with the press. The coworker of the Number 3 press inform ed the coworker of the second shift of the problem. At the end of each shift, ma intenance personal fill out the end of shift check sheet. The leak was noted and the operator looked over his desk into the area of the shear and saw the leak. The operator of Number 3 press saw Employee #1 looking into the area of the leak , standing outside the guarded fenced in area. The gate guards the area of the a rm gripper and has dimensions of 5 ft wide and 9 ft long. The gate hangs on a fr ame and is not secured. There are no interlocks. The operator told Employee #1 t hat they had two billets left to finish and it takes three minutes to run one bi llet. The operator returned to his duties with the press in automatic mode. The operator had his back to the press and was checking on inventory close by. The o perator said he turned around and saw the Employee #1 falling to the floor. The arm gripper had struck Employee #1, pinning and crushing him against the metal b ox. Employee #1 died.

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1030 · Bloodborne pathogens

29 CFR 1910.1030(c)(1)(iv)

(iv) The Exposure Control Plan shall be reviewed and updated at least annually and whenever necessary to reflect new or modified tasks and procedures which affect occupational exposure and to reflect new or revised employee positions with occupational exposure. The review and update of such plans shall also:

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(4)(i)

(4) Energy control procedure. (i) Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.

29 CFR 1910.147(c)(7)(i)(a)

(A) Each authorized employee shall receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control.

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.22 · General requirements

29 CFR 1910.303 · Electrical equipment, general requirements

Other alumina and aluminum production and processing employers in Georgia

Alert subscribers get notified of each newly cited employer in Georgia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.