OSHA SearchOSHA records by employer

Bondecroft-Water Plant: OSHA inspections and violations

Sparta, Tennessee · Water Supply and Irrigation Systems · NAICS 221310

1inspections
3citation items
$0current penalties
May 6, 2015last inspection

Bondecroft-Water Plant has one OSHA inspection on record in Tennessee.

OSHA opened it on May 6, 2015 as a planned inspection, in Sparta.

From that inspection OSHA issued 3 citation items: 3 serious.

OSHA did not attach a penalty to any of these citations.

Most often, OSHA cited 1910.106, flammable liquids (2 items).

For context, across all utility employers the median penalty per cited inspection since 2015 is $0. Bondecroft-Water Plant averages $0 over 1 cited inspection in that time.

Bondecroft-Water Plant: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Tennessee · latest 90 days of OSHA records

323employers cited

15 of them in the same industry

Get notified the morning OSHA posts each new citation in Tennessee: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Tennessee

Checking a subcontractor, a client or your own company? Watch Bondecroft-Water Plant and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340646629 OPENED MAY 6, 2015Closed

Planned · Complete · Safety · Local government · 4 employees at the site · Closed Aug 21, 2015

1000 Billy's Branch Road, Sparta, TN 38583 · Water Supply and Irrigation Systems · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.106(g)(8) · Flammable liquids
Serious$0$0Jul 13, 2015Final
Citation 1, item 2
29 CFR 1910.106(g)(9) · Flammable liquids
Serious$0$0Jul 13, 2015Final
Citation 1, item 3
29 CFR RULE 800-01-09-.07
Serious$0$0Jul 13, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(g)(8)

(8) Sources of ignition. In addition to the previous restrictions of this paragraph, the following shall apply: There shall be no smoking or open flames in the areas used for fueling, servicing fuel systems for internal combustion engines, receiving or dispensing of flammable liquids. Conspicuous and legible signs prohibiting smoking shall be posted within sight of the customer being served. The motors of all equipment being fueled shall be shut off during the fueling operation.

29 CFR 1910.106(g)(9)

(9) Fire control. Each service station shall be provided with at least one fire extinguisher having a minimum approved classification of 6 B, C, located so that an extinguisher, will be within 75 feet of each pump, dispenser, underground fill pipe opening, and lubrication or service room.

Other water supply and irrigation systems employers in Tennessee

Alert subscribers get notified of each newly cited employer in Tennessee the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.