OSHA SearchOSHA records by employer

Bora Construction Group, LLC.: OSHA inspections and violations

Jersey City, New Jersey · Roofing, Siding, and Insulation Material Merchant Wholesalers · NAICS 423330

1inspections
3citation items
$4,000current penalties
Mar 26, 2026last inspection

OSHA has inspected Bora Construction Group, LLC. once in New Jersey.

The inspection began on Mar 26, 2026 after a complaint, in Jersey City.

That inspection ended with 3 citation items: 2 serious and 1 other-than-serious.

Penalties were first proposed at $9,648 and now stand at $4,000, 59% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 2 items under 1926.451.

How that compares: the median penalty per cited inspection for wholesale employers since 2015 is $3,425, and Bora Construction Group, LLC. averages $4,000 (1 cited inspection).

Bora Construction Group, LLC.: OSHA citation items per year, 2026 to 2026
Citation items per year, by inspection date.

New Jersey · latest 90 days of OSHA records

269employers cited

Get notified the morning OSHA posts each new citation in New Jersey: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New Jersey

Checking a subcontractor, a client or your own company? Watch Bora Construction Group, LLC. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348835026 OPENED MAR 26, 2026Closed

Complaint · Partial · Safety · 2 employees at the site · Closed Jun 8, 2026

420 Liberty Ave., Jersey City, NJ 07307 · Roofing, Siding, and Insulation Material Merchant Wholesalers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(f)(6) · Scaffolds, general requirements
Other-than-serious$2,838$1,333Apr 2, 2026Final
Citation 1, item 2
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$3,972$1,333Apr 2, 2026Final
Citation 1, item 3
29 CFR 1926.452(j)(2) · Rules for each type of scaffold
Serious$2,838$1,334Apr 2, 2026Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(f)(6)

(6) The clearance between scaffolds and power lines shall be as follows: Scaffolds shall not be erected, used, dismantled, altered, or moved such that they or any conductive material handled on them might come closer to exposed and energized power lines than as follows:

29 CFR 1926.451(g)(1)

(g) Fall protection. (1) Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1) (i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.452(j)(2)

(2) Poles shall be secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. When the pump jack has to pass bracing already installed, an additional brace shall be installed approximately 4 feet (1.2 m) above the brace to be passed, and shall be left in place until the pump jack has been moved and the original brace reinstalled.

Other roofing, siding, and insulation material merchant wholesalers employers in New Jersey

Alert subscribers get notified of each newly cited employer in New Jersey the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.