OSHA SearchOSHA records by employer

BPC, L.P.: OSHA inspections and violations

Houston, Texas · Water and Sewer Line and Related Structures Construction · NAICS 237110

1inspections
4citation items
$23,713current penalties
Mar 14, 2024last inspection

OSHA has inspected BPC, L.P. once in Texas.

The inspection began on Mar 14, 2024 on a referral, in Houston.

That inspection ended with 4 citation items: 4 serious.

Penalties were first proposed at $33,876 and now stand at $23,713, 30% lower after settlements or reviews.

Trench protection comes up most often in these citations: 2 items under 1926.652.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and BPC, L.P. averages $23,713 (1 cited inspection).

BPC, L.P.: OSHA citation items per year, 2024 to 2024
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

394employers cited

12 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch BPC, L.P. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347351355 OPENED MAR 14, 2024Closed

Referral · Partial · Safety · 3 employees at the site · Closed Nov 26, 2024

7171 Buffalo Speedway, Houston, TX 77025 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.651(c)(2) · Excavations
Serious$11,292$0Sep 5, 2024Final
Citation 1, item 2
29 CFR 1926.50(e) · Medical services and first aid
Serious$11,292$7,904Sep 5, 2024Final
Citation 1, item 3b
29 CFR 1926.652(e)(1)(i) · Trench protection
Serious$0$7,904Sep 5, 2024Final
Citation 1, item 4
29 CFR 1926.652(c)(2)(i) · Trench protection
Serious$11,292$7,904Sep 5, 2024Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.50 · Medical services and first aid

29 CFR 1926.50(e)

(e) Proper equipment for prompt transportation of the injured person to a physician or hospital, or a communication system for contacting necessary ambulance service, shall be provided.

29 CFR 1926.651 · Excavations

29 CFR 1926.651(c)(2)

(2) Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees.

29 CFR 1926.652 · Trench protection

29 CFR 1926.652(c)(2)(i)

(2) Option (2)—Designs Using Manufacturer's Tabulated Data. (i) Design of support systems, shield systems, or other protective systems that are drawn from manufacturer's tabulated data shall be in accordance with all specifications, recommendations, and limitations issued or made by the manufacturer.

Other water and sewer line and related structures construction employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.