Brad Littlefield Builders: OSHA inspections and violations

Fryeburg, Maine · Residential Remodelers · NAICS 236118

1inspections
3citation items
$5,667current penalties
Feb 3, 2020last inspection

OSHA has inspected Brad Littlefield Builders once in Maine.

The inspection began on Feb 3, 2020 on a referral, in Fryeburg.

That inspection ended with 3 citation items: 2 serious and 1 other-than-serious.

Penalties were first proposed at $8,096 and now stand at $5,667, 30% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 2 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Brad Littlefield Builders averages $5,667 (1 cited inspection).

Brad Littlefield Builders: OSHA citation items per year, 2020 to 2020
Citation items per year, by inspection date.

Maine · latest 90 days of OSHA records

33employers cited

Get notified the morning OSHA posts each new citation in Maine: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Maine

Checking a subcontractor, a client or your own company? Watch Brad Littlefield Builders and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344600614 OPENED FEB 3, 2020Closed

Referral · Partial · Safety · 5 employees at the site · Closed May 26, 2020

297 Lovewells Pond Road, Fryeburg, ME 04037 · Residential Remodelers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$4,048$2,834Apr 28, 2020Final
Citation 1, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$4,048$2,834Apr 28, 2020Final
Citation 2, item 1
29 CFR 1926.1052(c)(1)(i) · Stairways in construction
Other-than-serious$0$0Apr 28, 2020Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1052 · Stairways in construction

29 CFR 1926.1052(c)(1)(i)

(i) At least one handrail; and

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.