OSHA SearchOSHA records by employer

Branch Building Group LLC: OSHA inspections and violations

Cheyenne, Wyoming · Framing Contractors · NAICS 238130

1inspections
4citation items
$3,848current penalties
Oct 10, 2017last inspection

OSHA inspectors have visited Branch Building Group LLC in Wyoming one time.

It opened on Oct 10, 2017, in Cheyenne.

In all, OSHA issued 4 citation items: 3 serious and 1 other-than-serious.

The proposed penalties came to $9,976; today they stand at $3,848, 61% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Branch Building Group LLC averages $3,848 across 1 cited inspection.

Branch Building Group LLC: OSHA citation items per year, 2017 to 2017
Citation items per year, by inspection date.

Wyoming · latest 90 days of OSHA records

31employers cited

Get notified the morning OSHA posts each new citation in Wyoming: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Wyoming

Checking a subcontractor, a client or your own company? Watch Branch Building Group LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342723574 OPENED OCT 10, 2017Closed

Unprogrammed other · Partial · Safety · 4 employees at the site · Closed Jan 3, 2018

1730 Dell Range Blvd., Cheyenne, WY 82001 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.25(a) · Housekeeping
Other-than-serious$2,850$0Nov 29, 2017Final
Citation 1, item 2a
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$3,563$2,405Nov 29, 2017Final
Citation 1, item 2b
29 CFR 1926.451(h)(2)(ii) · Scaffolds, general requirements
Serious$0$0Nov 29, 2017Final
Citation 1, item 3
29 CFR 1926.501(b)(2)(i) · Fall protection in construction
Serious$3,563$1,443Nov 29, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.25 · Housekeeping

29 CFR 1926.25(a)

(a) During the course of construction, alteration, or repairs, form and scrap lumber with protruding nails, and all other debris, shall be kept cleared from work areas, passageways, and stairs, in and around buildings or other structures.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(g)(4)(i)

(i) Guardrail systems shall be installed along all open sides and ends of platforms. Guardrail systems shall be installed before the scaffold is released for use by employees other than erection/dismantling crews.

29 CFR 1926.451(h)(2)(ii)

(ii) A toeboard shall be erected along the edge of platforms more than 10 feet (3.1 m) above lower levels for a distance sufficient to protect employees below, except on float (ship) scaffolds where an edging of 3/4 × 1 1/2 inch (2 × 4 cm) wood or equivalent may be used in lieu of toeboards;

29 CFR 1926.501 · Fall protection in construction

Other framing contractors employers in Wyoming

Alert subscribers get notified of each newly cited employer in Wyoming the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.