OSHA SearchOSHA records by employer

Branch Electric, LLC: OSHA inspections and violations

Perkinston, Mississippi · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

3inspections
5citation items
$5,634current penalties
Sep 14, 2016last inspection

OSHA has inspected Branch Electric, LLC 3 times in Mississippi since 2008.

The latest one began on Sep 14, 2016 to follow up on an earlier case, in Perkinston.

Those inspections ended with 5 citation items: 5 serious.

Penalties were first proposed at $9,090 and now stand at $5,634, 38% lower after settlements or reviews.

Job-site wiring comes up most often in these citations: 3 items under 1926.405.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Branch Electric, LLC averages $3,234 (1 cited inspection).

Branch Electric, LLC: OSHA citation items per year, 2008 to 2016
Citation items per year, by inspection date.

Mississippi · latest 90 days of OSHA records

15employers cited

Get notified the morning OSHA posts each new citation in Mississippi: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Mississippi

Checking a subcontractor, a client or your own company? Watch Branch Electric, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341780088 OPENED SEP 14, 2016Closed

Follow-up · Partial · Safety · 30 employees at the site · Closed Sep 20, 2016

Weeks Hall Building "b", Perkinston, MS 39573 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 341596195 OPENED JUN 30, 2016Closed

Complaint · Partial · Safety · 30 employees at the site · Closed Sep 21, 2016

Weeks Hall Building "b", Perkinston, MS 39573 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(f)(1) · Scaffolds, general requirements
Serious$5,390$3,234Aug 1, 2016Final

Inspection 311416242 OPENED AUG 21, 2008Closed

Planned · Complete · Safety · 7 employees at the site · Closed Mar 10, 2009

270 West 2nd Street, Pass Christian, MS 39571 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.403(b)(1) · Electrical equipment on job sites
Serious$875$570Sep 10, 2008Closed
Citation 1, item 2
29 CFR 1926.405(a)(2)(iic) · Job-site wiring
Serious$1,250$805Sep 10, 2008Closed
Citation 1, item 3
29 CFR 1926.405(b)(1) · Job-site wiring
Serious$875$570Sep 10, 2008Closed
Citation 1, item 4
29 CFR 1926.405(g)(2)(iv) · Job-site wiring
Serious$700$455Sep 10, 2008Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.403(b)(1)

(b) Examination, installation, and use of equipment—(1) Examination. The employer shall ensure that electrical equipment is free from recognized hazards that are likely to cause death or serious physical harm to employees. Safety of equipment shall be determined on the basis of the following considerations:

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(a)(2)(iic)

(C) Receptacles shall be of the grounding type. Unless installed in a complete metallic raceway, each branch circuit shall contain a separate equipment grounding conductor, and all receptacles shall be electrically connected to the grounding conductor. Receptacles for uses other than temporary lighting shall not be installed on branch circuits which supply temporary lighting. Receptacles shall not be connected to the same ungrounded conductor of multiwire circuits which supply temporary lighting.

29 CFR 1926.405(b)(1)

(b) Cabinets, boxes, and fittings—(1) Conductors entering boxes, cabinets, or fittings. Conductors entering boxes, cabinets, or fittings shall be protected from abrasion, and openings through which conductors enter shall be effectively closed. Unused openings in cabinets, boxes, and fittings shall also be effectively closed.

29 CFR 1926.451 · Scaffolds, general requirements

Other electrical contractors and other wiring installation contractors employers in Mississippi

Alert subscribers get notified of each newly cited employer in Mississippi the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.