Brashear Construction LLC: OSHA inspections and violations

Springdale, Ohio · Framing Contractors · NAICS 238130

1inspections
4citation items
$2,300current penalties
Apr 6, 2023last inspection

OSHA has inspected Brashear Construction LLC once in Ohio.

The inspection began on Apr 6, 2023 as a planned inspection, in Springdale; the case is still open.

That inspection ended with 4 citation items: 4 serious.

Penalties were first proposed at $14,064 and now stand at $2,300, 84% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 3 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Brashear Construction LLC averages $2,300 (1 cited inspection).

Brashear Construction LLC: OSHA citation items per year, 2023 to 2023
Citation items per year, by inspection date.

Ohio · latest 90 days of OSHA records

267employers cited

22 of them in the same industry

Get notified the morning OSHA posts each new citation in Ohio: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Ohio

Checking a subcontractor, a client or your own company? Watch Brashear Construction LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346619059 OPENED APR 6, 2023Open

Planned · Partial · Safety · 3 employees at the site · Open

11575 Springfield Pike, Springdale, OH 45246 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(a)(1) · Scaffolds, general requirements
Serious$4,688$2,300Jul 19, 2023Final
Citation 1, item 1b
29 CFR 1926.451(b)(2) · Scaffolds, general requirements
Serious$0$0Jul 19, 2023Final
Citation 1, item 1c
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$4,688$0Jul 19, 2023Final
Citation 1, item 1d
29 CFR 1926.454(a) · Scaffold training
Serious$4,688$0Jul 19, 2023Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(a)(1)

(a) Capacity. (1) Except as provided in paragraphs (a)(2), (a)(3), (a)(4), (a)(5) and (g) of this section, each scaffold and scaffold component shall be capable of supporting, without failure, its own weight and at least 4 times the maximum intended load applied or transmitted to it.

29 CFR 1926.451(b)(2)

(2) Except as provided in paragraphs (b)(2)(i) and (b)(2)(ii) of this section, each scaffold platform and walkway shall be at least 18 inches (46 cm) wide.

29 CFR 1926.451(g)(1)(vii)

(vii) For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee shall be protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.

29 CFR 1926.454 · Scaffold training

Other framing contractors employers in Ohio

Alert subscribers get notified of each newly cited employer in Ohio the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.