OSHA SearchOSHA records by employer

Brend Restoration, LLC.: OSHA inspections and violations

New York, New York · Commercial and Institutional Building Construction · NAICS 236220

4inspections
5citation items
$9,470current penalties
Apr 9, 2018last inspection

Since 2017, OSHA inspectors have visited Brend Restoration, LLC. in New York 4 times.

The most recent inspection opened on Apr 9, 2018 to follow up on an earlier case, in Chinatown.

In all, OSHA issued 5 citation items: 4 serious and 1 other-than-serious.

The proposed penalties came to $20,933; today they stand at $9,470, 55% less.

The rule cited most here is 1926.403 (electrical equipment on job sites), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Brend Restoration, LLC. averages $3,157 across 3 cited inspections.

Brend Restoration, LLC.: OSHA citation items per year, 2017 to 2018
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

362employers cited

13 of them in the same industry

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch Brend Restoration, LLC. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343070728 OPENED APR 9, 2018Closed

Follow-up · Complete · Safety · 11 employees at the site · Closed Apr 19, 2018

25 Hudson St, Chinatown, NY 10013 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 342441292 OPENED JUN 28, 2017Closed

Referral · Partial · Health · 12 employees at the site · Closed Feb 2, 2018

110 Franklin Street, New York, NY 10013 · Painting and Wall Covering Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.62(d)(1)(i) · Lead in construction
Serious$3,187$2,625Sep 15, 2017Final

Inspection 342397932 OPENED JUN 6, 2017Closed

Planned · Complete · Safety · 100 employees at the site · Closed Jul 9, 2019

158 Chambers Street, New York, NY 10007 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.1053(b)(1) · Ladders in construction
Other-than-serious$6,338$0Jul 21, 2017Final

Inspection 342397999 OPENED JUN 6, 2017Closed

Planned · Complete · Safety · 100 employees at the site · Closed May 16, 2019

25 Hudson Street, New York, NY 10013 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.300(b)(1) · Tools—Hand and Power: general requirements
Serious$6,338$3,803Nov 7, 2017Final
Citation 1, item 2a
29 CFR 1926.403(b)(2) · Electrical equipment on job sites
Serious$5,070$3,042Nov 7, 2017Final
Citation 1, item 2b
29 CFR 1926.403(i)(2)(i) · Electrical equipment on job sites
Serious$0$0Nov 7, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.300 · Tools—Hand and Power: general requirements

29 CFR 1926.300(b)(1)

(b) Guarding. (1) When power operated tools are designed to accommodate guards, they shall be equipped with such guards when in use.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.403(b)(2)

(2) Installation and use. Listed, labeled, or certified equipment shall be installed and used in accordance with instructions included in the listing, labeling, or certification.

29 CFR 1926.62 · Lead in construction

Other commercial and institutional building construction employers in New York

Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.