OSHA SearchOSHA records by employer

Brileya's Chrysler-Jeep, Inc.: OSHA inspections and violations

Rutland, Vermont · New Car Dealers · NAICS 441110

1inspections
3citation items
$1,400current penalties
Mar 22, 2018last inspection

Brileya's Chrysler-Jeep, Inc. has one OSHA inspection on record in Vermont.

OSHA opened it on Mar 22, 2018 as a planned inspection, in Rutland.

From that inspection OSHA issued 3 citation items: 2 serious and 1 other-than-serious.

OSHA proposed $2,826 in penalties. After settlements and reviews the total is $1,400, down 50%.

For context, across all retail employers the median penalty per cited inspection since 2015 is $1,750. Brileya's Chrysler-Jeep, Inc. averages $1,400 over 1 cited inspection in that time.

Brileya's Chrysler-Jeep, Inc.: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

Vermont · latest 90 days of OSHA records

28employers cited

Get notified the morning OSHA posts each new citation in Vermont: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Vermont

Checking a subcontractor, a client or your own company? Watch Brileya's Chrysler-Jeep, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343038808 OPENED MAR 22, 2018Closed

Planned · Complete · Safety · 20 employees at the site · Closed Nov 1, 2018

1253 Us Rte 7 North, Rutland, VT 05701 · New Car Dealers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.303(b)(7)(i) · Electrical equipment, general requirements
Serious$1,413$700Jun 28, 2018Final
Citation 1, item 2
29 CFR 1910.253(e)(3)(ii)(c)(3) · Gas welding and cutting
Serious$1,413$700Jun 28, 2018Final
Citation 2, item 1
29 CFR 1910.243(b)(2) · Guarding of portable powered tools
Other-than-serious$0$0Jun 28, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.243 · Guarding of portable powered tools

29 CFR 1910.243(b)(2)

(2) Airhose. Hose and hose connections used for conducting compressed air to utilization equipment shall be designed for the pressure and service to which they are subjected.

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.253(e)(3)(ii)(c)(3)

(C) Excessive back pressure of oxygen in the fuel-gas supply system. The three functions of the protective equipment may be combined in one device or may be provided by separate devices.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(b)(7)(i)

(i) Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings shall be effectively closed to afford protection substantially equivalent to the wall of the equipment.

Other new car dealers employers in Vermont

Alert subscribers get notified of each newly cited employer in Vermont the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.