Brinderson Constructors Inc has 6 OSHA inspections on record in California, the first in 1997.
OSHA's last visit started on Sep 12, 2022 as part of a related case, in Rodeo, and the case has not closed yet.
Across those inspections OSHA issued 7 citation items: 1 serious and 6 other-than-serious.
OSHA proposed $55,840 in penalties. After settlements and reviews the total is $38,490, down 31%.
For context, across all construction employers the median penalty per cited inspection since 2015 is $3,079. Brinderson Constructors Inc averages $17,995 over 2 cited inspections in that time.
Inspection 300871274 OPENED JUL 28, 2010Closed
Complaint · Partial · Safety · 28 employees at the site · Closed Nov 5, 2010
320 W. El Segundo Blvd., El Segundo, CA 90250 · Oil and Gas Pipeline and Related Structures Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Inspection 309904571 OPENED JAN 17, 2007Closed
Accident · Partial · Safety · 25 employees at the site · Closed Feb 15, 2007
2101 W Pacific Coast Highway, Wilmington, CA 90744 · Construction Sand and Gravel Mining · OSHA's record · Phone and website on Google Maps
Incident on Oct 20, 2006: Employee is injured when struck by pipe in the cheek
At approximately 10:15 a.m. on October 20, 2006, Employee #1 was working dismant ling an overhead pipe at the exchanger shell for the CRU-2 Exchanger. The pipe w as prepared for removal. The rigger rigged the pipe to the crane for lifting and the crane operator signaled to leave the area prior to the lift. Employee #1 wa s moving from the area when the lift started and the pipe shifted in its rigging . It struck him on the right cheek causing bruising and abrasion. He went to the hospital and returned to work the same day.
No citations from this inspection.
Incident on Jan 28, 1997: Two employees burned in pipeline fire
At approximately 8:45 a.m. on January 28, 1997, Employees #1 and #2 were install ing a vented plug at the south end of a new pipeline, while welding operations h ad started at the north end. A flash fire erupted from the south end of the pipe and both employees sustained facial burns. They were transported to Robert F. K ennedy Medical Center, from where Employee #1 was transferred to the Torrance (C A) Memorial Hospital Burn Center; Employee #2 was treated and released. Earlier, the south end of the new pipeline and the existing pipeline flanges had been un bolted and the blind opened, allowing a small amount of liquid from the existing line to enter the new line. The ensuing blast was ignited by the welding operat ions at the north end of the pipe.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|
| Citation 1, item 1 29 CFR 6815 C |
Other-than-serious | $2,250 | $2,500 | Jul 16, 1997 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.