Inspection 345278055 OPENED APR 28, 2021Closed
1731 Peach Leaf Street, Houston, TX 77039 · All Other Miscellaneous Nonmetallic Mineral Product Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.147(c)(1) · Lockout/tagout |
Serious | $3,901 | $3,901 | Aug 2, 2021 | Final |
| Citation 1, item 1b 29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts |
Serious | $0 | $0 | Aug 2, 2021 | Final |
| Citation 1, item 1c 29 CFR 1910.219(e)(1)(i) · Belts, pulleys and power-transmission parts |
Serious | $0 | $0 | Aug 2, 2021 | Final |
| Citation 1, item 2 29 CFR 1910.305(b)(2)(i) · Electrical wiring methods |
Serious | $3,901 | $3,901 | Aug 2, 2021 | Final |
| Citation 1, item 3a 29 CFR 1910.305(a)(2)(x) · Electrical wiring methods |
Serious | $3,901 | $3,901 | Aug 2, 2021 | Final |
| Citation 1, item 3b 29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods |
Serious | $0 | $0 | Aug 2, 2021 | Final |
| Citation 1, item 3c 29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods |
Serious | $0 | $0 | Aug 2, 2021 | Final |
| Citation 2, item 1 29 CFR 1910.1200(e)(1) · Hazard communication |
Other-than-serious | $0 | $0 | Aug 2, 2021 | Final |