OSHA SearchOSHA records by employer

Bro Builders Construction: OSHA inspections and violations

Herriman, Utah · Other Foundation, Structure, and Building Exterior Contractors · NAICS 238190

1inspections
6citation items
$2,250current penalties
Mar 31, 2020last inspection

Bro Builders Construction has one OSHA inspection on record in Utah.

OSHA opened it on Mar 31, 2020 on a referral, in Herriman.

From that inspection OSHA issued 6 citation items: 5 serious and 1 other-than-serious.

OSHA proposed $4,500 in penalties. After settlements and reviews the total is $2,250, down 50%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (4 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,079. Bro Builders Construction averages $2,250 over 1 cited inspection in that time.

Bro Builders Construction: OSHA citation items per year, 2020 to 2020
Citation items per year, by inspection date.

Want to know if OSHA cites Bro Builders Construction again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 344715925 OPENED MAR 31, 2020Closed

Referral · Partial · Safety · 4 employees at the site · Closed Jun 22, 2020

14975 South 3590 West, Herriman, UT 84096 · Other Foundation, Structure, and Building Exterior Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$1,500$750May 14, 2020Final
Citation 1, item 1b
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$0$0May 14, 2020Final
Citation 1, item 1c
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$0$0May 14, 2020Final
Citation 1, item 2
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$1,500$750May 14, 2020Final
Citation 1, item 3
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$1,500$750May 14, 2020Final
Citation 2, item 1
29 CFR 1926.503(b)(1) · Fall protection training in construction
Other-than-serious$0$0May 14, 2020Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(c)(2)

(2) Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.451(f)(3)

(3) Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

Other other foundation, structure, and building exterior contractors employers in Utah

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.