OSHA SearchOSHA records by employer

Brock Exteriors, LLC: OSHA inspections and violations

Wentzville, Missouri · Siding Contractors · NAICS 238170

2inspections
1citation items
$1,400current penalties
Oct 20, 2015last inspection

Since 2015, OSHA inspectors have visited Brock Exteriors, LLC in Missouri 2 times.

The most recent inspection opened on Oct 20, 2015 as a planned inspection, in Wentzville.

In all, OSHA issued 1 citation item: 1 serious.

The proposed penalties came to $2,800; today they stand at $1,400, 50% less.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Brock Exteriors, LLC averages $1,400 across 1 cited inspection.

Brock Exteriors, LLC: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Missouri · latest 90 days of OSHA records

120employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in Missouri: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Missouri

Checking a subcontractor, a client or your own company? Watch Brock Exteriors, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341036788 OPENED OCT 20, 2015Closed

Planned · Partial · Safety · 2 employees at the site · Closed Nov 16, 2015

Lonepine Drive, Wentzville, MO 63385 · Siding Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 340620681 OPENED MAY 7, 2015Closed

Planned · Partial · Safety · 2 employees at the site · Closed Jul 1, 2015

Lonepine Drive, Wentzville, MO 63385 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.452(j)(2) · Rules for each type of scaffold
Serious$2,800$1,400May 28, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.452(j)(2)

(2) Poles shall be secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. When the pump jack has to pass bracing already installed, an additional brace shall be installed approximately 4 feet (1.2 m) above the brace to be passed, and shall be left in place until the pump jack has been moved and the original brace reinstalled.

Other siding contractors employers in Missouri

Alert subscribers get notified of each newly cited employer in Missouri the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.