OSHA SearchOSHA records by employer

Brothers Steel Erectors LLC: OSHA inspections and violations

Wilder, Kentucky · Structural Steel and Precast Concrete Contractors · NAICS 238120

1inspections
2citation items
$7,000current penalties
Aug 14, 2025last inspection

Brothers Steel Erectors LLC has one OSHA inspection on record in Kentucky.

OSHA opened it on Aug 14, 2025, in Wilder, and the case has not closed yet.

From that inspection OSHA issued 2 citation items: 2 serious.

OSHA proposed $7,000 in penalties and the amount has not been reduced.

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Brothers Steel Erectors LLC averages $7,000 over 1 cited inspection in that time.

Brothers Steel Erectors LLC: OSHA citation items per year, 2025 to 2025
Citation items per year, by inspection date.

Kentucky · latest 90 days of OSHA records

188employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Kentucky: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Kentucky

Checking a subcontractor, a client or your own company? Watch Brothers Steel Erectors LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348442716 OPENED AUG 14, 2025Open

Unprogrammed other · Partial · Safety · 5 employees at the site · Open

5401 Alexandria Pike, Wilder, KY 41076 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$3,500$3,500Nov 10, 2025Final
Citation 1, item 2
29 CFR 1926.760(a)(1) · Fall protection
Serious$3,500$3,500Nov 10, 2025Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.453(b)(2)(v)

(v) A body belt shall be worn and a lanyard attached to the boom or basket when working from an aerial lift.

29 CFR 1926.760 · Fall protection

29 CFR 1926.760(a)(1)

(a) General requirements. (1) Except as provided by paragraph (a)(3) of this section, each employee engaged in a steel erection activity who is on a walking/working surface with an unprotected side or edge more than 15 feet (4.6 m) above a lower level shall be protected from fall hazards by guardrail systems, safety net systems, personal fall arrest systems, positioning device systems or fall restraint systems.