OSHA SearchOSHA records by employer

Brown Developments LLC: OSHA inspections and violations

Houlton, Maine · Site Preparation Contractors · NAICS 238910

2inspections
2citation items
$3,920current penalties
Aug 17, 2021last inspection

OSHA has inspected Brown Developments LLC 2 times in Maine since 2015.

The latest one began on Aug 17, 2021 on a referral, in Medway.

Those inspections ended with 2 citation items: 2 serious.

Penalties were first proposed at $5,600 and now stand at $3,920, 30% lower after settlements or reviews.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,078, and Brown Developments LLC averages $3,920 (1 cited inspection).

Brown Developments LLC: OSHA citation items per year, 2015 to 2021
Citation items per year, by inspection date.

Want to know if OSHA cites Brown Developments LLC again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 345485122 OPENED AUG 17, 2021Closed

Referral · Partial · Safety · 1 employee at the site · Closed Aug 17, 2021

Near Mile Marker 255 On I95, Medway, ME 04460 · Site Preparation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 340200039 OPENED JAN 22, 2015Closed

Planned · Complete · Safety · 3 employees at the site · Closed Mar 7, 2016

93 Military Street, Houlton, ME 04730 · Site Preparation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.300(b)(4)(ii) · Tools—Hand and Power: general requirements
Serious$2,800$1,960Feb 4, 2015Final
Citation 1, item 2
29 CFR 1926.405(b)(2) · Job-site wiring
Serious$2,800$1,960Feb 4, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.300 · Tools—Hand and Power: general requirements

29 CFR 1926.300(b)(4)(ii)

(ii) The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(b)(2)

(2) Covers and canopies. All pull boxes, junction boxes, and fittings shall be provided with covers. If metal covers are used, they shall be grounded. In energized installations each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.

Other site preparation contractors employers in Maine

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.