OSHA SearchOSHA records by employer

Brumall Manufacturing Corporation: OSHA inspections and violations

Mentor, Ohio · Current-Carrying Wiring Device Manufacturing · NAICS 335931

1inspections
3citation items
$5,650current penalties
Aug 8, 2017last inspection

Brumall Manufacturing Corporation has one OSHA inspection on record in Ohio.

OSHA opened it on Aug 8, 2017 on a referral, in Mentor.

From that inspection OSHA issued 3 citation items: 2 serious and 1 other-than-serious.

OSHA proposed $8,692 in penalties. After settlements and reviews the total is $5,650, down 35%.

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Brumall Manufacturing Corporation averages $5,650 over 1 cited inspection in that time.

It reported 1 severe injury to OSHA since 2015.

Brumall Manufacturing Corporation: OSHA citation items per year, 2017 to 2017
Citation items per year, by inspection date.

Ohio · latest 90 days of OSHA records

251employers cited

Get notified the morning OSHA posts each new citation in Ohio: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Ohio

Checking a subcontractor, a client or your own company? Watch Brumall Manufacturing Corporation and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342528163 OPENED AUG 8, 2017Closed

Referral · Partial · Safety · 24 employees at the site · Closed Nov 6, 2017

7850 Division Drive, Mentor, OH 44060 · Current-Carrying Wiring Device Manufacturing · OSHA's record · Phone and website on Google Maps

Incident on Jul 31, 2017: Employee is caught in saw and partially amputates finger

At 9:00 a.m. on July 31, 2017, an employee was placing material into the cutting area of his saw while the saw was running. His left index finger became caught in one of the holes in the material. Once the material blocked the sensor the saw cycled. When the saw blade cycled and contacted the work piece it was not held in place by the pin. Upon contact with the blade the work piece moved catching the operators finger between the work piece and/or saw table, causing a partial fingertip amputation. The employee as not hospitalized. hospitalized.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$3,622$2,354Aug 29, 2017Final
Citation 1, item 2
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$5,070$3,296Aug 29, 2017Final
Citation 2, item 1
29 CFR 1910.157(g)(2) · Portable fire extinguishers
Other-than-serious$0$0Aug 29, 2017Final

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Jul 31, 2017, Mentor: Amputation · amputations · fingertip(s)

An employee was putting a part in the circular saw. The employee's left index finger got caught in the connector hole and the saw came down resulting in a fingertip amputation.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(1)

(c) General—(1) Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, start up or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source, and rendered inoperative.

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.157(g)(2)

(2) The employer shall provide the education required in paragraph (g)(1) of this section upon initial employment and at least annually thereafter.

29 CFR 1910.212 · Machine guarding

29 CFR 1910.212(a)(3)(ii)

(ii) The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle.

Other current-carrying wiring device manufacturing employers in Ohio

Alert subscribers get notified of each newly cited employer in Ohio the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.