OSHA SearchOSHA records by employer

BRV Construction Services, Inc.: OSHA inspections and violations

Miami, Florida · Commercial and Institutional Building Construction · NAICS 236220

5inspections
18citation items
$18,915current penalties
Jun 27, 2019last inspection

Since 2002, OSHA inspectors have visited BRV Construction Services, Inc. in Florida 5 times.

The most recent inspection opened on Jun 27, 2019 as a planned inspection, in Sunrise.

In all, OSHA issued 18 citation items: 15 serious, 2 repeat and 1 other-than-serious.

The proposed penalties came to $22,277; today they stand at $18,915, 15% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 11 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. BRV Construction Services, Inc. averages $7,577 across 1 cited inspection.

BRV Construction Services, Inc. also files yearly injury logs with OSHA, summarized below.

BRV Construction Services, Inc.: OSHA citation items per year, 2002 to 2019
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

338employers cited

8 of them in the same industry

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch BRV Construction Services, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344115860 OPENED JUN 27, 2019Closed

Planned · Partial · Safety · 11 employees at the site · Closed Feb 24, 2020

10013 W. Sunset Strip, Sunrise, FL 33322 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$2,273$2,273Dec 20, 2019Final
Citation 1, item 2
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$5,304$5,304Dec 20, 2019Final

Inspection 313102972 OPENED JUN 24, 2009Closed

Planned · Complete · Safety · 4 employees at the site · Closed Jul 21, 2009

9560 Pines Blvd, Pembroke Pines, FL 33024 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Serious$700$525Jul 6, 2009Closed
Citation 1, item 2
29 CFR 1926.451(e)(9)(iv) · Scaffolds, general requirements
Serious$700$525Jul 6, 2009Closed
Citation 1, item 3a
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$700$525Jul 6, 2009Closed
Citation 1, item 3b
29 CFR 1926.451(g)(4)(xv) · Scaffolds, general requirements
Serious$0$0Jul 6, 2009Closed
Citation 2, item 1
29 CFR 1926.100(a) · Hard hats in construction
Repeat$2,400$1,800Jul 6, 2009Closed
Citation 2, item 2
29 CFR 1926.452(c)(2) · Rules for each type of scaffold
Repeat$2,400$1,800Jul 6, 2009Closed

Inspection 310211461 OPENED OCT 25, 2006Closed

Planned · Partial · Safety · 6 employees at the site · Closed Dec 14, 2006

14670 Sw 8th St., Miami, FL 33147 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.100(a) · Hard hats in construction
Serious$2,000$1,500Nov 17, 2006Closed
Citation 1, item 2
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$875$657Nov 17, 2006Closed
Citation 1, item 3
29 CFR 1926.451(c)(2)(ii) · Scaffolds, general requirements
Serious$875$656Nov 17, 2006Closed
Citation 1, item 4
29 CFR 1926.451(f)(15) · Scaffolds, general requirements
Serious$875$656Nov 17, 2006Closed
Citation 1, item 5
29 CFR 1926.452(c)(2) · Rules for each type of scaffold
Serious$875$656Nov 17, 2006Closed

Inspection 306178831 OPENED MAY 8, 2003Closed

Unprogrammed other · Complete · Safety · 3 employees at the site · Closed Oct 15, 2003

8515 Biscayne Boulevard, Miami, FL 33138 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$625$625May 23, 2003Closed
Citation 1, item 2
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$625$625May 23, 2003Closed
Citation 2, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Other-than-serious$0$0May 23, 2003Closed

Inspection 305503419 OPENED NOV 15, 2002Closed

Unprogrammed other · Complete · Safety · 2 employees at the site · Closed Jan 2, 2003

3500 Nw 87 Ave, Miami, FL 33178 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.100(a) · Hard hats in construction
Serious$525$394Dec 11, 2002Closed
Citation 1, item 2
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$525$394Dec 11, 2002Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2023, the Miami site logged 1 recordable injury or illness among about 39 workers: 2.1 per 100 full-time workers, against a median of 0.6 for its industry. Those cases cost 2 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
BRV Construction Services, Inc.
Miami · 2023
39 112.10.6

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(b)(1)(i)

(i) Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space between the platform and the uprights is no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary (for example, to fit around uprights when side brackets are used to extend the width of the platform).

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.501 · Fall protection in construction

Other commercial and institutional building construction employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.