OSHA SearchOSHA records by employer

Bryan Steam LLC: OSHA inspections and violations

Peru, Indiana · Power Boiler and Heat Exchanger Manufacturing · NAICS 332410

9inspections
56citation items
$6,968current penalties
Jun 9, 2020last inspection

OSHA has inspected Bryan Steam LLC 9 times in Indiana since 1973.

The latest one began on Jun 9, 2020 on a referral, in Peru.

Those inspections ended with 56 citation items: 21 serious and 35 other-than-serious.

Penalties were first proposed at $13,915 and now stand at $6,968, 50% lower after settlements or reviews.

Hexavalent chromium comes up most often in these citations: 12 items under 1910.1026.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Bryan Steam LLC averages $1,625 (1 cited inspection).

Bryan Steam LLC also files yearly injury logs with OSHA, summarized below.

Bryan Steam LLC: OSHA citation items per year, 1973 to 2020
Citation items per year, by inspection date.

Indiana · latest 90 days of OSHA records

75employers cited

Get notified the morning OSHA posts each new citation in Indiana: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Indiana

Checking a subcontractor, a client or your own company? Watch Bryan Steam LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344782289 OPENED JUN 9, 2020Closed

Referral · Partial · Safety · 85 employees at the site · Closed Jan 19, 2021

783 North Chili Avenue, Peru, IN 46970 · Plumbing and Heating Equipment and Supplies (Hydronics) Merchant Wholesalers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$2,500$1,625Nov 17, 2020Final

Inspection 312091622 OPENED OCT 30, 2008Closed

Complaint · Partial · Health · 153 employees at the site · Closed May 7, 2009

783 North Chili Avenue, Peru, IN 46970 · Power Boiler and Heat Exchanger Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.146(c)(2) · Permit-required confined spaces
Other-than-serious$825$0Feb 9, 2009Closed
Citation 1, item 2
29 CFR 1910.252(c)(2)(ic) · Welding fire safety
Other-than-serious$825$0Feb 9, 2009Closed
Citation 1, item 3a
29 CFR 1910.1026(d)(1) · Hexavalent chromium
Other-than-serious$1,375$0Feb 9, 2009Closed
Citation 1, item 3b
29 CFR 1910.1200(h)(1) · Hazard communication
Other-than-serious$0$0Feb 9, 2009Closed
Citation 1, item 4a
29 CFR 1910.1026(h)(1) · Hexavalent chromium
Serious$1,375$962Feb 9, 2009Closed
Citation 1, item 4b
29 CFR 1910.1026(h)(2)(i) · Hexavalent chromium
Serious$0$0Feb 9, 2009Closed
Citation 1, item 4c
29 CFR 1910.1026(h)(3)(i) · Hexavalent chromium
Serious$0$0Feb 9, 2009Closed
Citation 1, item 5a
29 CFR 1910.1026(i)(1) · Hexavalent chromium
Other-than-serious$1,375$0Feb 9, 2009Closed
Citation 1, item 5b
29 CFR 1910.1026(i)(2) · Hexavalent chromium
Other-than-serious$0$0Feb 9, 2009Closed
Citation 1, item 5c
29 CFR 1910.1026(i)(3)(ii) · Hexavalent chromium
Serious$0$962Feb 9, 2009Closed
Citation 1, item 5d
29 CFR 1910.1026(i)(4)(i) · Hexavalent chromium
Serious$0$0Feb 9, 2009Closed
Citation 1, item 5e
29 CFR 1910.1026(i)(5) · Hexavalent chromium
Serious$0$0Feb 9, 2009Closed
Citation 1, item 5f
29 CFR 1910.1026(j)(1)(i) · Hexavalent chromium
Serious$0$0Feb 9, 2009Closed
Citation 1, item 6a
29 CFR 1910.1026(l)(2)(i) · Hexavalent chromium
Serious$1,375$962Feb 9, 2009Closed
Citation 1, item 6b
29 CFR 1910.1026(l)(2)(ii) · Hexavalent chromium
Serious$0$0Feb 9, 2009Closed
Citation 2, item 1
29 CFR 1910.134(c)(2)(i) · Respiratory protection
Other-than-serious$0$0Feb 9, 2009Closed

Inspection 127420222 OPENED APR 12, 2002Closed

Planned · Complete · Safety · 212 employees at the site · Closed Oct 25, 2002

783 North Chili Avenue, Peru, IN 46970 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$675$335May 17, 2002Closed
Citation 1, item 2
29 CFR 1910.212(a)(5) · Machine guarding
Serious$675$335May 17, 2002Closed
Citation 1, item 3a
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Serious$675$335May 17, 2002Closed
Citation 1, item 3b
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$0$0May 17, 2002Closed
Citation 1, item 4
29 CFR 1910.219(c)(2)(i) · Belts, pulleys and power-transmission parts
Serious$675$335May 17, 2002Closed
Citation 1, item 5
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$675$225May 17, 2002Closed
Citation 2, item 1 Other-than-serious$0$0May 17, 2002Closed
Citation 2, item 2
29 CFR 1910.254(d)(7) · Arc welding and cutting
Other-than-serious$0$0May 17, 2002Closed
Citation 2, item 3
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Other-than-serious$0$0May 17, 2002Closed
Citation 2, item 4
29 CFR 1910.1200(f)(5)(i) · Hazard communication
Other-than-serious$0$0May 17, 2002Closed

Inspection 114986680 OPENED NOV 2, 1993Closed

Planned · Complete · Safety · 168 employees at the site · Closed Jan 10, 1994

State Rd 19 North, Peru, IN 46970 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 2, item 1
29 CFR 1910.305(b)(1) · Electrical wiring methods
Other-than-serious$0$0Dec 3, 1993Closed
Citation 2, item 2
29 CFR 1910.37(k)(2) · Exit routes
Other-than-serious$0$0Dec 3, 1993Closed

Inspection 101981447 OPENED JUN 30, 1987Closed

Planned · Complete · Safety · 115 employees at the site · Closed Apr 8, 1988

State Rd 19 North, Peru, IN 46970 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.243(c)(3) · Guarding of portable powered tools
Serious$180$180Jul 21, 1987Closed
Citation 2, item 1
29 CFR 1910.252(e)(2)(iii) · Welding fire safety
Other-than-serious$0$0Jul 21, 1987Closed
Citation 2, item 2
29 CFR 1910.304(f)(5)(v) · Grounding and circuit protection
Other-than-serious$0$0Jul 21, 1987Closed

Inspection 215162363 OPENED AUG 11, 1983Closed

Planned · Complete · Safety · 102 employees at the site · Closed Aug 23, 1983

State Road 19 North, Peru, IN 46970 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 215172750 OPENED AUG 31, 1982Closed

Follow-up · Partial · Safety · 79 employees at the site · Closed Sep 7, 1982

State Rd 19 North, Peru, IN 46970 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 215201062 OPENED MAY 26, 1982Closed

Planned · Complete · Safety · 105 employees at the site · Closed Sep 7, 1982

State Road 19 North, Peru, IN 46970 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Serious$240$240Jun 10, 1982Closed
Citation 1, item 2a
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$180$180Jun 10, 1982Closed
Citation 1, item 2b
29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Jun 10, 1982Closed
Citation 1, item 3
29 CFR 1910.243(c)(3) · Guarding of portable powered tools
Serious$240$240Jun 10, 1982Closed
Citation 2, item 1
29 CFR 1910.22(d)(1) · General requirements
Other-than-serious$0$0Jun 10, 1982Closed
Citation 2, item 2
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Other-than-serious$0$0Jun 10, 1982Closed
Citation 2, item 3
29 CFR 1910.303(f) · Electrical equipment, general requirements
Other-than-serious$0$0Jun 10, 1982Closed
Citation 2, item 4
29 CFR 1910.305(g)(1)(iii) · Electrical wiring methods
Other-than-serious$0$0Jun 10, 1982Closed
1 older inspection

Inspection 215343401 OPENED FEB 23, 1973Closed

Complaint · Complete · Safety · 85 employees at the site · Closed Mar 10, 1984

Po Box 27, Peru, IN 46970 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.215(a)(1) · Grinders and abrasive wheels
Other-than-serious$0$0Mar 2, 1973Closed
Citation 1, item 2
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Other-than-serious$0$0Mar 2, 1973Closed
Citation 1, item 3
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Other-than-serious$0$0Mar 2, 1973Closed
Citation 1, item 4
29 CFR 1910.219(b)(1) · Belts, pulleys and power-transmission parts
Other-than-serious$0$0Mar 2, 1973Closed
Citation 1, item 5
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Other-than-serious$0$0Mar 2, 1973Closed
Citation 1, item 6
29 CFR 1910.106(e)(2)(ivd)(0) · Flammable liquids
Other-than-serious$25$25Mar 2, 1973Closed
Citation 1, item 7
29 CFR 1910.106(e)(6)(i) · Flammable liquids
Other-than-serious$0$0Mar 2, 1973Closed
Citation 1, item 8
29 CFR 1910.106(e)(6)(ii) · Flammable liquids
Other-than-serious$0$0Mar 2, 1973Closed
Citation 1, item 9
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Other-than-serious$0$0Mar 2, 1973Closed
Citation 1, item 10
29 CFR 1910.213(h)(1) · Woodworking machinery
Other-than-serious$0$0Mar 2, 1973Closed
Citation 1, item 11
29 CFR 1910.213(h)(4) · Woodworking machinery
Other-than-serious$0$0Mar 2, 1973Closed
Citation 1, item 12
29 CFR 1910.252(b)(4)(ixc)(0) · Welding fire safety
Other-than-serious$0$0Mar 2, 1973Closed
Citation 1, item 13
29 CFR 1910.252(b)(4)(i) · Welding fire safety
Other-than-serious$0$0Mar 2, 1973Closed
Citation 1, item 14
29 CFR 1910.23(d)(1)(iii) · Guarding floor and wall openings and holes
Other-than-serious$25$25Mar 2, 1973Closed
Citation 1, item 15
29 CFR 1910.252(a)(2)(ivc)(0) · Welding fire safety
Other-than-serious$0$0Mar 2, 1973Closed
Citation 1, item 16
29 CFR 1910.106(g)(8) · Flammable liquids
Other-than-serious$0$0Mar 2, 1973Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Peru site logged 3 recordable injuries or illnesses among about 77 workers: 4.5 per 100 full-time workers, against a median of 2.8 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Bryan Steam, LLC
Peru · 2025
77 304.52.8
Bryan Steam LLC
Peru · 2020
80 426.22.8

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1026 · Hexavalent chromium

29 CFR 1910.1026(d)(1)

(d) Exposure determination—(1) General. Each employer who has a workplace or work operation covered by this section shall determine the 8-hour TWA exposure for each employee exposed to chromium (VI). This determination shall be made in accordance with either paragraph (d)(2) or paragraph (d)(3) of this section.

29 CFR 1910.1026(h)(1)

(h) Protective work clothing and equipment—(1) Provision and use. Where a hazard is present or is likely to be present from skin or eye contact with chromium (VI), the employer shall provide appropriate personal protective clothing and equipment at no cost to employees, and shall ensure that employees use such clothing and equipment.

29 CFR 1910.1026(i)(1)

(i) Hygiene areas and practices—(1) General. Where protective clothing and equipment is required, the employer shall provide change rooms in conformance with 29 CFR 1910.141. Where skin contact with chromium (VI) occurs, the employer shall provide washing facilities in conformance with 29 CFR 1910.141. Eating and drinking areas provided by the employer shall also be in conformance with § 1910.141.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.146 · Permit-required confined spaces

29 CFR 1910.184 · Slings

29 CFR 1910.212 · Machine guarding

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.22 · General requirements

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.243 · Guarding of portable powered tools

29 CFR 1910.252 · Welding fire safety

29 CFR 1910.254 · Arc welding and cutting

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.37 · Exit routes

Other power boiler and heat exchanger manufacturing employers in Indiana

Alert subscribers get notified of each newly cited employer in Indiana the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.