Bucher Hydraulics, Inc: OSHA inspections and violations
Newaygo, Michigan · Fluid Power Valve and Hose Fitting Manufacturing · NAICS 332912
4inspections
25citation items
$55,100current penalties
Feb 4, 2026last inspection
Since 2016, OSHA inspectors have visited Bucher Hydraulics, Inc in Michigan 4 times.
The most recent inspection opened on Feb 4, 2026 as a planned inspection, in Newaygo.
In all, OSHA issued 25 citation items: 14 serious, 3 repeat and 8 other-than-serious.
The proposed penalties came to $110,200; today they stand at $55,100, 50% less.
The rule cited most here is 1910.147 (lockout/tagout), 9 times.
Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Bucher Hydraulics, Inc averages $13,775 across 4 cited inspections.
Bucher Hydraulics, Inc also files yearly injury logs with OSHA, summarized below.
Citation items per year, by inspection date.
Michigan · latest 90 days of OSHA records
665employers cited
Get notified the morning OSHA posts each new citation in Michigan: the employer, the site address, the rules broken and the penalty.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2025, the Grand Rapids site logged 14 recordable injuries or illnesses among about 208 workers: 7.4 per 100 full-time workers, against a median of 1.9 for its industry. Those cases cost 15 days away from work.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
Bucher Hydraulics Inc - Grand Rapids
Grand Rapids · 2025
208
14
1
7.4
1.9
Bucher Hydraulics Inc - Newaygo
Newaygo · 2025
136
10
2
9.3
1.9
Bucher Hydraulics, Inc. Grand Rapids, MI
Grand Rapids · 2024
225
5
0
2.2
1.9
Bucher Hydraulics - Grand Rapids
Grand Rapids · 2021
186
2
1
0.9
1.9
Bucher Hydraulics - Newaygo
Newaygo · 2021
140
4
1
2.4
1.9
Included with any plan: 4 more yearly logs from these sites, back to 2020, with each site's average rate over its latest three years. Already a subscriber? Sign in.
(4) Energy control procedure. (i) Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.
29 CFR 1910.147(c)(4)(ii)
(ii) The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the following:
29 CFR 1910.147(c)(6)(i)
(6) Periodic inspection. (i) The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.
Alert subscribers get notified of each newly cited employer in Michigan the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.