OSHA SearchOSHA records by employer

Bucher Hydraulics, Inc: OSHA inspections and violations

Newaygo, Michigan · Fluid Power Valve and Hose Fitting Manufacturing · NAICS 332912

4inspections
25citation items
$55,100current penalties
Feb 4, 2026last inspection

Since 2016, OSHA inspectors have visited Bucher Hydraulics, Inc in Michigan 4 times.

The most recent inspection opened on Feb 4, 2026 as a planned inspection, in Newaygo.

In all, OSHA issued 25 citation items: 14 serious, 3 repeat and 8 other-than-serious.

The proposed penalties came to $110,200; today they stand at $55,100, 50% less.

The rule cited most here is 1910.147 (lockout/tagout), 9 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Bucher Hydraulics, Inc averages $13,775 across 4 cited inspections.

Bucher Hydraulics, Inc also files yearly injury logs with OSHA, summarized below.

Bucher Hydraulics, Inc: OSHA citation items per year, 2016 to 2026
Citation items per year, by inspection date.

Michigan · latest 90 days of OSHA records

665employers cited

Get notified the morning OSHA posts each new citation in Michigan: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Michigan

Checking a subcontractor, a client or your own company? Watch Bucher Hydraulics, Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348724519 OPENED FEB 4, 2026Closed

Planned · Partial · Safety · 114 employees at the site · Closed Apr 13, 2026

201 Cooperative Center Dr, Newaygo, MI 49337 · Fluid Power Valve and Hose Fitting Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(f)(3)(ii) · Lockout/tagout
Serious$4,000$2,000Mar 18, 2026Final
Citation 2, item 1
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Repeat$25,000$12,500Mar 18, 2026Final
Citation 3, item 1
29 CFR 1910.147(c)(4)(ii) · Lockout/tagout
Other-than-serious$0$0Mar 18, 2026Final
Citation 4, item 1
29 CFR 408.22141B
Other-than-serious$1,000$500Mar 18, 2026Final

Inspection 348674771 OPENED JAN 8, 2026Closed

Referral · Partial · Safety · 150 employees at the site · Closed Mar 10, 2026

1363 Michigan Street Northeast, Grand Rapids, MI 49503 · Fluid Power Pump and Motor Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 408.12321(1)
Serious$7,000$3,500Feb 10, 2026Final
Citation 1, item 1b
29 CFR 408.12341(1)
Serious$0$0Feb 10, 2026Final
Citation 1, item 1c
29 CFR 408.12371
Serious$0$0Feb 10, 2026Final
Citation 1, item 1d
29 CFR 408.12373
Serious$0$0Feb 10, 2026Final
Citation 1, item 2a
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$7,000$3,500Feb 10, 2026Final
Citation 1, item 2b
29 CFR 1910.147(c)(4)(ii) · Lockout/tagout
Serious$0$0Feb 10, 2026Final
Citation 2, item 1a
29 CFR 1910.147(c)(7)(i) · Lockout/tagout
Repeat$35,000$17,500Feb 10, 2026Final
Citation 2, item 1b
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Repeat$0$0Feb 10, 2026Final
Citation 3, item 1
29 CFR 408.22141B
Other-than-serious$1,000$500Feb 10, 2026Final

Inspection 345276034 OPENED APR 28, 2021Closed

Planned · Partial · Safety · 128 employees at the site · Closed Jun 23, 2021

201 Cooperative Center Dr, Newaygo, MI 49337 · Fluid Power Valve and Hose Fitting Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 408.10034(1)
Serious$6,300$3,150May 26, 2021Final
Citation 1, item 2a
29 CFR 1910.147(c)(7)(i) · Lockout/tagout
Serious$4,800$2,400May 26, 2021Final
Citation 1, item 2b
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Serious$0$0May 26, 2021Final
Citation 2, item 1
29 CFR 408.22141(2)
Other-than-serious$900$450May 26, 2021Final

Inspection 341951150 OPENED DEC 7, 2016Closed

Complaint · Partial · Safety · 125 employees at the site · Closed Mar 24, 2017

201 Cooperative Center Dr, Newaygo, MI 49337 · Fluid Power Valve and Hose Fitting Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 408.10034(9)
Serious$2,800$1,400Mar 3, 2017Final
Citation 1, item 2
29 CFR 408.10731(1)
Serious$6,300$3,150Mar 3, 2017Final
Citation 1, item 3
29 CFR 408.11441
Serious$6,300$3,150Mar 3, 2017Final
Citation 1, item 4
29 CFR 408.11852(1)
Serious$2,800$1,400Mar 3, 2017Final
Citation 2, item 1a
29 CFR 408.10632(5)
Other-than-serious$0$0Mar 3, 2017Final
Citation 2, item 1b
29 CFR 408.11222(5)
Other-than-serious$0$0Mar 3, 2017Final
Citation 2, item 1c
29 CFR 408.11222(1)
Other-than-serious$0$0Mar 3, 2017Final
Citation 2, item 2
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Other-than-serious$0$0Mar 3, 2017Final

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Grand Rapids site logged 14 recordable injuries or illnesses among about 208 workers: 7.4 per 100 full-time workers, against a median of 1.9 for its industry. Those cases cost 15 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
Bucher Hydraulics Inc - Grand Rapids
Grand Rapids · 2025
208 1417.41.9
Bucher Hydraulics Inc - Newaygo
Newaygo · 2025
136 1029.31.9
Bucher Hydraulics, Inc. Grand Rapids, MI
Grand Rapids · 2024
225 502.21.9
Bucher Hydraulics - Grand Rapids
Grand Rapids · 2021
186 210.91.9
Bucher Hydraulics - Newaygo
Newaygo · 2021
140 412.41.9

Included with any plan: 4 more yearly logs from these sites, back to 2020, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(4)(i)

(4) Energy control procedure. (i) Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.

29 CFR 1910.147(c)(4)(ii)

(ii) The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the following:

29 CFR 1910.147(c)(6)(i)

(6) Periodic inspection. (i) The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.

29 CFR 1910.305 · Electrical wiring methods

Other fluid power valve and hose fitting manufacturing employers in Michigan

Alert subscribers get notified of each newly cited employer in Michigan the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.