OSHA SearchOSHA records by employer

Buena Vida Corp.: OSHA inspections and violations

Brooklyn, New York · Nursing Care Facilities (Skilled Nursing Facilities) · NAICS 623110

2inspections
7citation items
$14,250current penalties
Mar 23, 2018last inspection

Buena Vida Corp. has 2 OSHA inspections on record in New York, the first in 2007.

OSHA's last visit started on Mar 23, 2018 after a complaint, in Brooklyn.

Across those inspections OSHA issued 7 citation items: 6 serious and 1 other-than-serious.

OSHA proposed $29,966 in penalties. After settlements and reviews the total is $14,250, down 52%.

Most often, OSHA cited 1910.147, lockout/tagout (2 items).

For context, across all health care employers the median penalty per cited inspection since 2015 is $1,050. Buena Vida Corp. averages $12,000 over 1 cited inspection in that time.

Buena Vida Corp. also files yearly injury logs with OSHA, summarized below.

Buena Vida Corp.: OSHA citation items per year, 2007 to 2018
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

353employers cited

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch Buena Vida Corp. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343039335 OPENED MAR 23, 2018Closed

Complaint · Partial · Safety · 270 employees at the site · Closed Feb 4, 2022

48 Cedar Street, Brooklyn, NY 11221 · Nursing Care Facilities (Skilled Nursing Facilities) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$7,391$4,435Aug 21, 2018Final
Citation 1, item 1b Serious$0$0Aug 21, 2018Final
Citation 1, item 2
29 CFR 1910.303(b)(7)(iv) · Electrical equipment, general requirements
Serious$5,543$3,130Aug 21, 2018Final
Citation 1, item 5a
29 CFR 1910.304(g)(5) · Grounding and circuit protection
Serious$7,391$4,435Aug 21, 2018Final
Citation 1, item 5b
29 CFR 1910.305(b)(1)(i) · Electrical wiring methods
Serious$5,543$0Aug 21, 2018Final
Citation 2, item 1
29 CFR 1904.29(b)(2) · Injury and illness log
Other-than-serious$1,848$0Aug 21, 2018Final

Inspection 311225908 OPENED SEP 6, 2007Closed

Complaint · Partial · Safety · 300 employees at the site · Closed Dec 5, 2007

48 Cedar Street, Brooklyn, NY 11221 · Nursing Care Facilities (Skilled Nursing Facilities) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Serious$2,250$2,250Nov 15, 2007Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2023, the Brooklyn site logged 6 recordable injuries or illnesses among about 289 workers: 0.0 per 100 full-time workers. Those cases cost 110 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
Buena Vida SNF
Brooklyn · 2023
289 660.0–

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.29 · Injury and illness log

29 CFR 1904.29(b)(2)

(2) What do I need to do to complete the OSHA 301 Incident Report? You must complete an OSHA 301 Incident Report form, or an equivalent form, for each recordable injury or illness entered on the OSHA 300 Log.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(1)

(c) General—(1) Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, start up or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source, and rendered inoperative.

29 CFR 1910.147(c)(5)(ii)(d)

(D) Identifiable. Lockout devices and tagout devices shall indicate the identity of the employee applying the device(s).

29 CFR 1910.212 · Machine guarding

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

Other nursing care facilities (skilled nursing facilities) employers in New York

Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.