OSHA SearchOSHA records by employer

Builders First Source: OSHA inspections and violations

Anchorage, Alaska · Other Construction Material Merchant Wholesalers · NAICS 423390

3inspections
7citation items
$134,455current penalties
Dec 23, 2019last inspection

OSHA has inspected Builders First Source 3 times in Alaska since 2016.

The latest one began on Dec 23, 2019 after a complaint, in Anchorage.

Those inspections ended with 7 citation items: 2 serious, 2 repeat and 3 other-than-serious.

Penalties were first proposed at $184,536 and now stand at $134,455, 27% lower after settlements or reviews.

Machine guarding comes up most often in these citations: 3 items under 1910.212.

How that compares: the median penalty per cited inspection for wholesale employers since 2015 is $3,427, and Builders First Source averages $44,818 (3 cited inspections).

Builders First Source: OSHA citation items per year, 2016 to 2019
Citation items per year, by inspection date.

Want to know if OSHA cites Builders First Source again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 344527106 OPENED DEC 23, 2019Closed

Complaint · Partial · Safety · 44 employees at the site · Closed Jun 10, 2020

4600 Lois Dr, Anchorage, AK 99518 · Other Construction Material Merchant Wholesalers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Repeat$104,192$83,332Apr 16, 2020Final
Citation 2, item 1
29 CFR 1910.213(b)(1) · Woodworking machinery
Serious$8,335$6,668Apr 16, 2020Final

Inspection 344393111 OPENED OCT 22, 2019Closed

Referral · Complete · Safety · 49 employees at the site · Closed Feb 6, 2020

4600 Lois Dr, Anchorage, AK 99517 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Incident on Oct 21, 2019: Employee's hand is lacerated by sawblade

At 1:00 p.m. on October 21, 2019, an employee was cutting material using a chop saw when he reached under the guard to remove cut material and suffered a laceration to his hand between his index and middle fingers. The employee was hospitalized for treatment.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Repeat$62,009$37,205Nov 5, 2019Final
Citation 2, item 1
29 CFR AS 18.60.058 (A)
Other-than-serious$5,000$5,000Nov 5, 2019Final

Inspection 341906931 OPENED NOV 14, 2016Closed

Referral · Partial · Safety · 38 employees at the site · Closed Mar 3, 2017

1700 W Parks Hwy, Wasilla, AK 99623 · Other Construction Material Merchant Wholesalers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$5,000$2,250Jan 13, 2017Final
Citation 2, item 1a
29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods
Other-than-serious$0$0Jan 13, 2017Final
Citation 2, item 1b
29 CFR 1910.303(b)(1)(i) · Electrical equipment, general requirements
Other-than-serious$0$0Jan 13, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.212 · Machine guarding

29 CFR 1910.212(a)(3)(ii)

(ii) The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle.

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.213(b)(1)

(b) Machine controls and equipment. (1) A mechanical or electrical power control shall be provided on each machine to make it possible for the operator to cut off the power from each machine without leaving his position at the point of operation.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(b)(1)(i)

(i) Suitability for installation and use in conformity with the provisions of this subpart;

29 CFR 1910.305 · Electrical wiring methods

Other other construction material merchant wholesalers employers in Alaska

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.