Building Portfolio Investments: OSHA inspections and violations

San Antonio, Texas · Residential Remodelers · NAICS 236118

1inspections
4citation items
$2,608current penalties
Jan 25, 2017last inspection

OSHA inspectors have visited Building Portfolio Investments in Texas one time.

It opened on Jan 25, 2017 as a planned inspection, in San Antonio.

In all, OSHA issued 4 citation items: 4 serious.

The proposed penalties came to $6,519; today they stand at $2,608, 60% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 4 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Building Portfolio Investments averages $2,608 across 1 cited inspection.

Building Portfolio Investments: OSHA citation items per year, 2017 to 2017
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

394employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Building Portfolio Investments and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342052313 OPENED JAN 25, 2017Closed

Planned · Partial · Safety · 4 employees at the site · Closed Jul 7, 2017

1305 Mulberry Ave, San Antonio, TX 78209 · Residential Remodelers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Serious$2,173$869Mar 10, 2017Final
Citation 1, item 2a
29 CFR 1926.451(e)(6)(i) · Scaffolds, general requirements
Serious$2,173$869Mar 10, 2017Final
Citation 1, item 2b
29 CFR 1926.451(e)(6)(vi) · Scaffolds, general requirements
Serious$0$0Mar 10, 2017Final
Citation 1, item 3
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$2,173$869Mar 10, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)(i)

(i) Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space between the platform and the uprights is no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary (for example, to fit around uprights when side brackets are used to extend the width of the platform).

29 CFR 1926.451(e)(6)(i)

(i) Be specifically designed and constructed for use as ladder rungs;

29 CFR 1926.451(e)(6)(vi)

(vi) Have a maximum spacing between rungs of 16 3/4 inches (43 cm). Non-uniform rung spacing caused by joining end frames together is allowed, provided the resulting spacing does not exceed 16 3/4 inches (43 cm).

Other residential remodelers employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.