Inspection 349205526 OPENED OCT 7, 2026Open
167 Cosby Lane, Tazewell, VA 24651 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection so far.
Building Specialists, Inc. has 10 OSHA inspections on record in Virginia, the first in 1999.
OSHA's last visit started on Oct 7, 2026 after a complaint, in Tazewell, and the case has not closed yet.
Across those inspections OSHA issued 8 citation items: 1 serious and 7 other-than-serious.
OSHA proposed $2,400 in penalties. After settlements and reviews the total is $1,500, down 38%.
Most often, OSHA cited 1926.62, lead in construction (3 items).
For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Building Specialists, Inc. averages $1,200 over 1 cited inspection in that time.
Building Specialists, Inc. also files yearly injury logs with OSHA, summarized below.
Virginia · latest 90 days of OSHA records
248employers cited
21 of them in the same industry
Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Virginia
Checking a subcontractor, a client or your own company? Watch Building Specialists, Inc. and get notified the morning OSHA posts a new citation for it.
Watch this company167 Cosby Lane, Tazewell, VA 24651 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection so far.
414 N Main St, Blacksburg, VA 24060 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.451(f)(3) · Scaffolds, general requirements |
Other-than-serious | $600 | $600 | Feb 5, 2026 | Final |
| Citation 1, item 2 29 CFR 1926.501(b)(4)(ii) · Fall protection in construction |
Other-than-serious | $600 | $600 | Feb 5, 2026 | Final |
201 Campbell Ave, Roanoke, VA 24011 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Marshal Ave, Fieldale, VA 24089 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
3755 Brambleton Ave, Roanoke, VA 24018 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
N. Tazewell Train Station Depot Renovation 135 Railroad Avenue, North Tazewell, VA 24630 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Jackson House 8 E Washington St, Lexington, VA 24450 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1210 Patterson Ave. Sw, Roanoke, VA 24016 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
15 And 17 Church Avenue, Roanoke, VA 24011 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 2, item 1 29 CFR 1926.62(d)(1)(i) · Lead in construction |
Other-than-serious | $0 | $0 | Sep 28, 2005 | Closed |
| Citation 2, item 2 29 CFR 1926.62(d)(2)(ia) · Lead in construction |
Other-than-serious | $0 | $0 | Sep 28, 2005 | Closed |
| Citation 2, item 3 29 CFR 1926.62(l)(2)(ii) · Lead in construction |
Other-than-serious | $0 | $0 | Sep 28, 2005 | Closed |
801 University City Boulevard, Blacksburg, VA 24060 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.451(e)(1) · Scaffolds, general requirements |
Serious | $600 | $300 | Jun 9, 1999 | Final |
| Citation 1, item 1b 29 CFR 1926.451(g)(1) · Scaffolds, general requirements |
Other-than-serious | $0 | $0 | Jun 9, 1999 | Final |
| Citation 1, item 2 29 CFR 1926.501(b)(4)(ii) · Fall protection in construction |
Other-than-serious | $600 | $0 | Jun 9, 1999 | Final |
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2023, the Roanoke site logged 0 recordable injuries or illnesses among about 16 workers: 0.0 per 100 full-time workers, against a median of 1.8 for its industry.
| Site and year | Workers | Cases | Days-away cases | Rate | Industry median |
|---|---|---|---|---|---|
| 114 Day AVe Roanoke · 2023 | 16 | 0 | 0 | 0.0 | 1.8 |
| Building Specialist Roanoke · 2021 | 22 | 2 | 2 | 12.5 | 1.8 |
Included with any plan: 2 more yearly logs from these sites, back to 2020, with each site's average rate over its latest three years. Already a subscriber? Sign in.
See plansCurrent text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.451(e)(1)
(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.
29 CFR 1926.451(f)(3)
(3) Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity.
29 CFR 1926.451(g)(1)
(g) Fall protection. (1) Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1) (i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers.
Alert subscribers get notified of each newly cited employer in Virginia the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.