OSHA SearchOSHA records by employer

Built Strong Construction, LLC: OSHA inspections and violations

San Antonio, Texas · Masonry Contractors · NAICS 238140

2inspections
10citation items
$17,000current penalties
Aug 8, 2025last inspection

Built Strong Construction, LLC has 2 OSHA inspections on record in Texas, the first in 2022.

OSHA's last visit started on Aug 8, 2025 as part of a related case, in Madisonville, and the case has not closed yet.

Across those inspections OSHA issued 10 citation items: 10 serious.

OSHA proposed $36,534 in penalties. After settlements and reviews the total is $17,000, down 53%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (6 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Built Strong Construction, LLC averages $8,500 over 2 cited inspections in that time.

Built Strong Construction, LLC: OSHA citation items per year, 2022 to 2025
Citation items per year, by inspection date.

Want to know if OSHA cites Built Strong Construction, LLC again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 348429762 OPENED AUG 8, 2025Open

Unprogrammed related · Partial · Safety · 1 employee at the site · Open

605 East Main Street, Madisonville, TX 77864 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$3,972$2,500Jan 30, 2026Final
Citation 1, item 2 Serious$3,972$2,500Jan 30, 2026Final

Inspection 345734180 OPENED JAN 19, 2022Closed

Planned · Partial · Safety · 7 employees at the site · Closed Jul 31, 2023

243 W. Loop 1604 S., San Antonio, TX 78245 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Serious$3,729$3,000Mar 3, 2022Final
Citation 1, item 1b
29 CFR 1926.451(c)(2)(ii) · Scaffolds, general requirements
Serious$3,729$0Mar 3, 2022Final
Citation 1, item 1c
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$2,486$0Mar 3, 2022Final
Citation 1, item 2
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$4,351$2,000Mar 3, 2022Final
Citation 1, item 3
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$3,729$2,000Mar 3, 2022Final
Citation 1, item 4
29 CFR 1926.451(h)(2)(ii) · Scaffolds, general requirements
Serious$2,486$1,000Mar 3, 2022Final
Citation 1, item 5
29 CFR 1926.454(a) · Scaffold training
Serious$3,729$2,000Mar 3, 2022Final
Citation 1, item 6
29 CFR 1926.1153(g)(1) · Silica dust in construction
Serious$4,351$2,000Mar 3, 2022Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1153 · Silica dust in construction

29 CFR 1926.1153(g)(1)

(g) Written exposure control plan. (1) The employer shall establish and implement a written exposure control plan that contains at least the following elements:

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)(i)

(i) Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space between the platform and the uprights is no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary (for example, to fit around uprights when side brackets are used to extend the width of the platform).

29 CFR 1926.451(c)(2)(ii)

(ii) Unstable objects shall not be used to support scaffolds or platform units.

29 CFR 1926.454 · Scaffold training

29 CFR 1926.600 · Equipment

Other masonry contractors employers in Texas

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.