Inspection 348597949 OPENED OCT 24, 2025Closed
1257 Park Ave., New York, NY 10029 · Masonry Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Since 2019, OSHA inspectors have visited Bulls Eye Contractor Inc. in New York 3 times.
The most recent inspection opened on Oct 24, 2025 after a complaint, in New York.
In all, OSHA issued 5 citation items: 5 serious.
The penalties, $13,880 in total, stand where OSHA first set them.
The rule cited most here is 1926.451 (scaffolds, general requirements), 3 times.
Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Bulls Eye Contractor Inc. averages $13,880 across 1 cited inspection.
New York · latest 90 days of OSHA records
360employers cited
7 of them in the same industry
Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in New York
Checking a subcontractor, a client or your own company? Watch Bulls Eye Contractor Inc. and get notified the morning OSHA posts a new citation for it.
Watch this company1257 Park Ave., New York, NY 10029 · Masonry Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
501 West 144th Street, New York, NY 10031 · Masonry Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
501 West 144th Street, New York, NY 10031 · Masonry Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.451(d)(5)(iii) · Scaffolds, general requirements |
Serious | $2,892 | $2,892 | Feb 28, 2020 | Final |
| Citation 1, item 2 29 CFR 1926.451(e)(1) · Scaffolds, general requirements |
Serious | $4,048 | $4,048 | Feb 28, 2020 | Final |
| Citation 1, item 3 29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements |
Serious | $4,048 | $4,048 | Feb 28, 2020 | Final |
| Citation 1, item 4a 29 CFR 1926.1053(b)(1) · Ladders in construction |
Serious | $2,892 | $2,892 | Feb 28, 2020 | Final |
| Citation 1, item 4b 29 CFR 1926.1053(b)(4) · Ladders in construction |
Serious | $0 | $0 | Feb 28, 2020 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.1053(b)(1)
(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.
29 CFR 1926.1053(b)(4)
(4) Ladders shall be used only for the purpose for which they were designed.
29 CFR 1926.451(d)(5)(iii)
(iii) Secured against movement by tiebacks installed at right angles to the face of the building or structure, or opposing angle tiebacks shall be installed and secured to a structurally sound point of anchorage on the building or structure. Sound points of anchorage include structural members, but do not include standpipes, vents, other piping systems, or electrical conduit.
Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.