Busada Manufacturing Corporation: OSHA inspections and violations

Louisa, Virginia · Plastics Material and Resin Manufacturing · NAICS 325211

2inspections
27citation items
$862current penalties
Sep 29, 2021last inspection

OSHA has inspected Busada Manufacturing Corporation 2 times in Virginia since 1998.

The latest one began on Sep 29, 2021 as a planned inspection, in Louisa.

Those inspections ended with 27 citation items: 21 serious and 6 other-than-serious.

Penalties were first proposed at $1,725 and now stand at $862, 50% lower after settlements or reviews.

Belts, pulleys and power-transmission parts comes up most often in these citations: 4 items under 1910.219.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $4,500, and Busada Manufacturing Corporation averages $0 (1 cited inspection).

Busada Manufacturing Corporation: OSHA citation items per year, 1998 to 2021
Citation items per year, by inspection date.

Virginia · latest 90 days of OSHA records

249employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Virginia

Checking a subcontractor, a client or your own company? Watch Busada Manufacturing Corporation and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345552194 OPENED SEP 29, 2021Closed

Planned · Complete · Safety · 15 employees at the site · Closed Nov 10, 2021

78 Rescue Lane, Louisa, VA 23093 · Plastics Material and Resin Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.37(b)(6) · Exit routes
Other-than-serious$0$0Oct 13, 2021Final

Inspection 301816765 OPENED APR 14, 1998Closed

Planned · Complete · Safety · 17 employees at the site · Closed Sep 21, 1998

78 Rescue Lane, Louisa County Industrial Air Park, Louisa, VA 23093 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 510001 A
Serious$375$188Apr 30, 1998Closed
Citation 1, item 1b
29 CFR 1910.212(a)(1) · Machine guarding
Serious$0$0Apr 30, 1998Closed
Citation 1, item 1c
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$0$0Apr 30, 1998Closed
Citation 1, item 1d
29 CFR 1910.219(c)(4)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Apr 30, 1998Closed
Citation 1, item 1e
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$0$0Apr 30, 1998Closed
Citation 1, item 1f
29 CFR 1910.219(e)(1)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Apr 30, 1998Closed
Citation 1, item 1g
29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Apr 30, 1998Closed
Citation 1, item 2a
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$225$112Apr 30, 1998Closed
Citation 1, item 2b
29 CFR 1910.147(c)(5)(i) · Lockout/tagout
Serious$0$0Apr 30, 1998Closed
Citation 1, item 2c
29 CFR 1910.147(c)(7)(i) · Lockout/tagout
Serious$0$0Apr 30, 1998Closed
Citation 1, item 3
29 CFR 1910.151(b) · First aid and eyewash
Serious$225$112Apr 30, 1998Closed
Citation 1, item 4a
29 CFR 1910.157(g)(1) · Portable fire extinguishers
Serious$225$112Apr 30, 1998Closed
Citation 1, item 4b
29 CFR 1910.157(g)(2) · Portable fire extinguishers
Serious$0$0Apr 30, 1998Closed
Citation 1, item 5a
29 CFR 1910.215(a)(2) · Grinders and abrasive wheels
Serious$225$112Apr 30, 1998Closed
Citation 1, item 5b
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Serious$0$0Apr 30, 1998Closed
Citation 1, item 5c
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$0$0Apr 30, 1998Closed
Citation 1, item 5d
29 CFR 1910.215(d)(3) · Grinders and abrasive wheels
Serious$0$0Apr 30, 1998Closed
Citation 1, item 6
29 CFR 1910.242(b) · Hand and power tools
Serious$225$112Apr 30, 1998Closed
Citation 1, item 7a
29 CFR 1910.304(f)(4) · Grounding and circuit protection
Serious$225$112Apr 30, 1998Closed
Citation 1, item 7b
29 CFR 1910.305(g)(1)(iii) · Electrical wiring methods
Serious$0$0Apr 30, 1998Closed
Citation 1, item 7c
29 CFR 1910.305(g)(2)(ii) · Electrical wiring methods
Serious$0$0Apr 30, 1998Closed
Citation 2, item 1
29 CFR ARM000205 A
Other-than-serious$0$0Apr 30, 1998Closed
Citation 2, item 2
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Other-than-serious$0$0Apr 30, 1998Closed
Citation 2, item 3
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Other-than-serious$0$0Apr 30, 1998Closed
Citation 2, item 4
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Apr 30, 1998Closed
Citation 2, item 5
29 CFR 1910.1200(h) · Hazard communication
Other-than-serious$0$0Apr 30, 1998Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.1200(h)

(h) Post-mortem data: Increased incidence and/or severity of post-mortem findings may be indicative of maternal toxicity. This can include gross or microscopic pathological findings or organ weight data, including absolute organ weight, organ-to-body weight ratio, or organ-to-brain weight ratio. When supported by findings of adverse histopathological effects in the affected organ(s), the observation of a significant change in the average weight of suspected target organ(s) of treated dams (mothers), compared to those in the control group, may be considered evidence of maternal toxicity.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(1)

(c) General—(1) Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, start up or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source, and rendered inoperative.

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.212 · Machine guarding

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.37 · Exit routes

Other plastics material and resin manufacturing employers in Virginia

Alert subscribers get notified of each newly cited employer in Virginia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.