OSHA SearchOSHA records by employer

BVD Construction LLC: OSHA inspections and violations

Portland, Oregon · New Single-Family Housing Construction (except For-Sale Builders) · NAICS 236115

1inspections
9citation items
$200current penalties
Oct 27, 2023last inspection

OSHA has inspected BVD Construction LLC once in Oregon.

The inspection began on Oct 27, 2023 after a complaint, in Portland.

That inspection ended with 9 citation items: 5 serious and 4 other-than-serious.

Penalties were first proposed at $200 and still stand at $200.

Lead in construction comes up most often in these citations: 6 items under 1926.62.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and BVD Construction LLC averages $200 (1 cited inspection).

BVD Construction LLC: OSHA citation items per year, 2023 to 2023
Citation items per year, by inspection date.

Oregon · latest 90 days of OSHA records

388employers cited

15 of them in the same industry

Get notified the morning OSHA posts each new citation in Oregon: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Oregon

Checking a subcontractor, a client or your own company? Watch BVD Construction LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347068439 OPENED OCT 27, 2023Closed

Complaint · Partial · Health · 5 employees at the site · Closed May 20, 2024

9003 N Kimball Ave, Portland, OR 97219 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.62(d)(1)(i) · Lead in construction
Serious$100$100Feb 21, 2024Final
Citation 1, item 2a
29 CFR 1926.62(d)(2)(v)(c) · Lead in construction
Serious$100$100Feb 21, 2024Final
Citation 1, item 2b
29 CFR 1926.62(d)(2)(v)(d) · Lead in construction
Serious$0$0Feb 21, 2024Final
Citation 1, item 2c
29 CFR 1926.62(d)(2)(v)(e) · Lead in construction
Serious$0$0Feb 21, 2024Final
Citation 1, item 2d
29 CFR 1926.62(d)(2)(v)(f) · Lead in construction
Serious$0$0Feb 21, 2024Final
Citation 2, item 3
29 CFR 1910.134(c)(1) · Respiratory protection
Other-than-serious$0$0Feb 21, 2024Final
Citation 2, item 4
29 CFR 1926.62(e)(2)(i) · Lead in construction
Other-than-serious$0$0Feb 21, 2024Final
Citation 2, item 5
29 CFR 1910.134(e)(1) · Respiratory protection
Other-than-serious$0$0Feb 21, 2024Final
Citation 2, item 6
29 CFR 1910.134(f)(2) · Respiratory protection
Other-than-serious$0$0Feb 21, 2024Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(c)(1)

(1) The test instrument must have an effective audio-warning device, or a visual-warning device in the form of a screen tracing, that indicates when the test subject fails to hold his or her breath during the test. The test must be terminated and restarted from the beginning when the test subject fails to hold his or her breath during the test. The test subject then may be refitted and retested.

29 CFR 1910.134(e)(1)

(1) General. The employer shall provide a medical evaluation to determine the employee's ability to use a respirator, before the employee is fit tested or required to use the respirator in the workplace. The employer may discontinue an employee's medical evaluations when the employee is no longer required to use a respirator.

29 CFR 1910.134(f)(2)

(2) Deep breathing. In a normal standing position, the subject shall breathe slowly and deeply, taking caution so as not to hyperventilate.

29 CFR 1926.62 · Lead in construction

Other new single-family housing construction (except for-sale builders) employers in Oregon

Alert subscribers get notified of each newly cited employer in Oregon the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.