OSHA SearchOSHA records by employer

Bybee Excavation, LLC: OSHA inspections and violations

Ammon, Idaho · Site Preparation Contractors · NAICS 238910

1inspections
5citation items
$5,000current penalties
Jun 5, 2019last inspection

Bybee Excavation, LLC has one OSHA inspection on record in Idaho.

OSHA opened it on Jun 5, 2019 after a complaint, in Ammon.

From that inspection OSHA issued 5 citation items: 5 serious.

OSHA proposed $7,956 in penalties. After settlements and reviews the total is $5,000, down 37%.

Most often, OSHA cited 1926.651, excavations (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Bybee Excavation, LLC averages $5,000 over 1 cited inspection in that time.

Bybee Excavation, LLC: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

Idaho · latest 90 days of OSHA records

61employers cited

Get notified the morning OSHA posts each new citation in Idaho: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Idaho

Checking a subcontractor, a client or your own company? Watch Bybee Excavation, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344068671 OPENED JUN 5, 2019Closed

Complaint · Partial · Safety · 3 employees at the site · Closed Oct 8, 2019

65th South, Ammon, ID 83401 · Site Preparation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.21(b)(2) · Construction safety training
Serious$3,978$2,000Aug 29, 2019Final
Citation 1, item 1b
29 CFR 1926.651(j)(2) · Excavations
Serious$0$0Aug 29, 2019Final
Citation 1, item 1c
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$0$0Aug 29, 2019Final
Citation 1, item 2a
29 CFR 1926.651(k)(1) · Excavations
Serious$3,978$3,000Aug 29, 2019Final
Citation 1, item 2b
29 CFR 1926.652(a)(1) · Trench protection
Serious$0$0Aug 29, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.21 · Construction safety training

29 CFR 1926.21(b)(2)

(2) The employer shall instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury.

29 CFR 1926.651 · Excavations

29 CFR 1926.651(j)(2)

(2) Employees shall be protected from excavated or other materials or equipment that could pose a hazard by falling or rolling into excavations. Protection shall be provided by placing and keeping such materials or equipment at least 2 feet (.61 m) from the edge of excavations, or by the use of retaining devices that are sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary.

29 CFR 1926.652 · Trench protection

Other site preparation contractors employers in Idaho

Alert subscribers get notified of each newly cited employer in Idaho the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.