OSHA SearchOSHA records by employer

C&E Builders LLC: OSHA inspections and violations

Reno, Nevada · Framing Contractors · NAICS 238130

7inspections
4citation items
$26,754current penalties
Mar 3, 2017last inspection

OSHA has inspected C&E Builders LLC 7 times in Nevada since 2013.

The latest one began on Mar 3, 2017 on a referral, in Reno.

Those inspections ended with 4 citation items: 2 serious and 2 repeat.

Penalties were first proposed at $33,880 and now stand at $26,754, 21% lower after settlements or reviews.

Fall protection in construction comes up most often in these citations: 3 items under 1926.501.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and C&E Builders LLC averages $7,350 (2 cited inspections).

C&E Builders LLC also files yearly injury logs with OSHA, summarized below.

C&E Builders LLC: OSHA citation items per year, 2013 to 2017
Citation items per year, by inspection date.

Want to know if OSHA cites C&E Builders LLC again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 342152261 OPENED MAR 3, 2017Closed

Referral · Partial · Safety · 9 employees at the site · Closed Jul 12, 2017

224 Stewart St., Reno, NV 89502 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.416(a)(1) · Electrical safety in construction
Serious$700$700Apr 24, 2017Final

Inspection 341305795 OPENED MAR 8, 2016Closed

Complaint · Partial · Safety · 6 employees at the site · Closed Mar 8, 2016

5821 Stephens Rd., Reno, NV 89511 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 341306629 OPENED MAR 8, 2016Closed

Complaint · Partial · Safety · 6 employees at the site · Closed Mar 8, 2016

12245 Mystic Sands, Spanish Springs, NV 89441 · Framing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 340767144 OPENED JUL 8, 2015Closed

Unprogrammed related · Partial · Safety · 6 employees at the site · Closed Jul 12, 2017

400 Mt. Rose Street, Reno, NV 89509 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Repeat$17,500$14,000Nov 4, 2015Final

Inspection 317723732 OPENED MAY 19, 2014Closed

Referral · Partial · Safety · 40 employees at the site · Closed Jan 27, 2016

2145 Ascot Lane, Reno, NV 89502 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Repeat$10,780$8,624Aug 28, 2014Closed

Inspection 317364958 OPENED NOV 13, 2013Closed

Referral · Partial · Safety · 4 employees at the site · Closed Nov 13, 2013

Lot 147 Eagle Peak Drive, Sparks, NV 89441 · Framing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 317217966 OPENED AUG 7, 2013Closed

Referral · Partial · Safety · 8 employees at the site · Closed Apr 24, 2014

2145 Ascot Lane, Reno, NV 89502 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$4,900$3,430Sep 18, 2013Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2017, the Reno site logged 11 recordable injuries or illnesses among about 65 workers: 15.1 per 100 full-time workers, against a median of 2.8 for its industry. Those cases cost 75 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
C&E Builders
Reno · 2017
65 11115.12.8

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.416(a)(1)

(a) Protection of employees. (1) No employer shall permit an employee to work in such proximity to any part of an electric power circuit that the employee could contact the electric power circuit in the course of work, unless the employee is protected against electric shock by deenergizing the circuit and grounding it or by guarding it effectively by insulation or other means.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(13)

(13) Residential construction. Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of § 1926.502.

Other framing contractors employers in Nevada

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.