OSHA SearchOSHA records by employer

C & E Construction of Sheboygan, LLC: OSHA inspections and violations

Franklin, Wisconsin · Roofing Contractors · NAICS 238160

3inspections
32citation items
$7,942current penalties
Jun 11, 2021last inspection

OSHA has inspected C & E Construction of Sheboygan, LLC 3 times in Wisconsin since 2004.

The latest one began on Jun 11, 2021 after a complaint, in Sheboygan.

Those inspections ended with 32 citation items: 29 serious and 3 other-than-serious.

Penalties were first proposed at $30,372 and now stand at $7,942, 74% lower after settlements or reviews.

Asbestos in construction comes up most often in these citations: 13 items under 1926.1101.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and C & E Construction of Sheboygan, LLC averages $6,342 (1 cited inspection).

C & E Construction of Sheboygan, LLC: OSHA citation items per year, 2004 to 2021
Citation items per year, by inspection date.

Wisconsin · latest 90 days of OSHA records

216employers cited

47 of them in the same industry

Get notified the morning OSHA posts each new citation in Wisconsin: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Wisconsin

Checking a subcontractor, a client or your own company? Watch C & E Construction of Sheboygan, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345359905 OPENED JUN 11, 2021Closed

Complaint · Partial · Health · 5 employees at the site · Closed Mar 1, 2022

2122 Henry Street, Sheboygan, WI 53081 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$4,915$2,438Dec 1, 2021Final
Citation 1, item 1b
29 CFR 1910.134(c)(3) · Respiratory protection
Serious$0$0Dec 1, 2021Final
Citation 1, item 1c
29 CFR 1910.134(f)(2) · Respiratory protection
Serious$0$0Dec 1, 2021Final
Citation 1, item 1d
29 CFR 1910.134(k) · Respiratory protection
Serious$0$0Dec 1, 2021Final
Citation 1, item 1e
29 CFR 1926.62(d)(2)(v)(a) · Lead in construction
Serious$0$0Dec 1, 2021Final
Citation 1, item 1f
29 CFR 1926.62(f)(2)(i) · Lead in construction
Serious$0$0Dec 1, 2021Final
Citation 1, item 1g
29 CFR 1926.1101(h)(1) · Asbestos in construction
Serious$0$0Dec 1, 2021Final
Citation 1, item 1h
29 CFR 1926.1101(h)(2)(i) · Asbestos in construction
Serious$0$0Dec 1, 2021Final
Citation 1, item 1i
29 CFR 1926.1101(m)(1)(i)(b) · Asbestos in construction
Serious$0$0Dec 1, 2021Final
Citation 1, item 2a
29 CFR 1926.21(b)(2) · Construction safety training
Serious$2,106$1,053Dec 1, 2021Final
Citation 1, item 2b
29 CFR 1926.62(d)(2)(v)(f) · Lead in construction
Serious$0$0Dec 1, 2021Final
Citation 1, item 2c
29 CFR 1926.1101(k)(9)(i) · Asbestos in construction
Serious$0$0Dec 1, 2021Final
Citation 1, item 3a
29 CFR 1926.62(d)(1)(i) · Lead in construction
Serious$2,106$1,053Dec 1, 2021Final
Citation 1, item 3b
29 CFR 1926.62(d)(1)(iii) · Lead in construction
Serious$0$0Dec 1, 2021Final
Citation 1, item 3c
29 CFR 1926.62(d)(2)(v)(b) · Lead in construction
Serious$2,106$0Dec 1, 2021Final
Citation 1, item 3d
29 CFR 1926.62(g)(1) · Lead in construction
Serious$0$0Dec 1, 2021Final
Citation 1, item 3e
29 CFR 1926.62(d)(2)(v)(c) · Lead in construction
Serious$2,106$0Dec 1, 2021Final
Citation 1, item 3f
29 CFR 1926.62(i)(2)(i) · Lead in construction
Serious$0$0Dec 1, 2021Final
Citation 1, item 6a
29 CFR 1926.1101(f)(1)(i) · Asbestos in construction
Serious$2,809$1,404Dec 1, 2021Final
Citation 1, item 6b
29 CFR 1926.1101(f)(2)(i) · Asbestos in construction
Serious$0$0Dec 1, 2021Final
Citation 1, item 6c
29 CFR 1926.1101(g)(1)(i) · Asbestos in construction
Serious$2,106$0Dec 1, 2021Final
Citation 1, item 6d
29 CFR 1926.1101(g)(1)(ii) · Asbestos in construction
Serious$0$0Dec 1, 2021Final
Citation 1, item 6e
29 CFR 1926.1101(l)(2) · Asbestos in construction
Serious$0$0Dec 1, 2021Final
Citation 1, item 6f
29 CFR 1926.1101(g)(7)(i) · Asbestos in construction
Serious$2,809$0Dec 1, 2021Final
Citation 1, item 6g
29 CFR 1926.1101(o)(1) · Asbestos in construction
Serious$0$0Dec 1, 2021Final
Citation 1, item 6h
29 CFR 1926.1101(g)(8)(iii)(a) · Asbestos in construction
Serious$2,809$0Dec 1, 2021Final
Citation 1, item 6i
29 CFR 1926.1101(i)(1) · Asbestos in construction
Serious$2,106$0Dec 1, 2021Final
Citation 2, item 1a
29 CFR 1910.1018(e)(1)(i) · Inorganic arsenic
Other-than-serious$394$394Dec 1, 2021Final
Citation 2, item 1b Other-than-serious$0$0Dec 1, 2021Final

Inspection 307060517 OPENED APR 5, 2005Closed

Planned · Partial · Safety · 8 employees at the site · Closed Aug 5, 2005

17900 Lincoln, New Berlin, WI 53146 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.503(c)(2) · Fall protection training in construction
Serious$1,000$1,000Apr 21, 2005Closed

Inspection 307053777 OPENED JAN 8, 2004Closed

Planned · Partial · Safety · 8 employees at the site · Closed Mar 15, 2004

9251 South 51st Street Building J, Franklin, WI 53132 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$1,500$600Jan 20, 2004Closed
Citation 1, item 2
29 CFR 1926.503(a)(1) · Fall protection training in construction
Other-than-serious$1,500$0Jan 20, 2004Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1018 · Inorganic arsenic

29 CFR 1910.1018(e)(1)(i)

(e) Exposure monitoring—(1) General. (i) Determinations of airborne exposure levels shall be made from air samples that are representative of each employee's exposure to inorganic arsenic over an eight (8) hour period.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(c)(1)

(1) The test instrument must have an effective audio-warning device, or a visual-warning device in the form of a screen tracing, that indicates when the test subject fails to hold his or her breath during the test. The test must be terminated and restarted from the beginning when the test subject fails to hold his or her breath during the test. The test subject then may be refitted and retested.

29 CFR 1910.134(c)(3)

(3) The test operator shall direct the stream of irritant smoke from the smoke tube toward the faceseal area of the test subject, using the low flow pump or the squeeze bulb. The test operator shall begin at least 12 inches from the facepiece and move the smoke stream around the whole perimeter of the mask. The operator shall gradually make two more passes around the perimeter of the mask, moving to within six inches of the respirator.

29 CFR 1926.1101 · Asbestos in construction

29 CFR 1926.1127 · Cadmium

29 CFR 1926.21 · Construction safety training

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

29 CFR 1926.62 · Lead in construction

Other roofing contractors employers in Wisconsin

Alert subscribers get notified of each newly cited employer in Wisconsin the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.