C & N Associates, L. L. C.: OSHA inspections and violations

Baltimore, Maryland · Framing Contractors · NAICS 238130

1inspections
2citation items
$187current penalties
Oct 18, 2019last inspection

OSHA inspectors have visited C & N Associates, L. L. C. in Maryland one time.

It opened on Oct 18, 2019 as a planned inspection, in Baltimore.

In all, OSHA issued 2 citation items: 2 serious.

The penalties, $187 in total, stand where OSHA first set them.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. C & N Associates, L. L. C. averages $187 across 1 cited inspection.

C & N Associates, L. L. C.: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

Maryland · latest 90 days of OSHA records

175employers cited

18 of them in the same industry

Get notified the morning OSHA posts each new citation in Maryland: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Maryland

Checking a subcontractor, a client or your own company? Watch C & N Associates, L. L. C. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344386248 OPENED OCT 18, 2019Closed

Planned · Complete · Safety · 5 employees at the site · Closed Dec 31, 2019

6101 Hillen Rd, Baltimore, MD 21239 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.404(f)(6) · Ground-fault protection on job sites
Serious$187$187Dec 12, 2019Final
Citation 1, item 1b
29 CFR 1926.405(j)(1)(i) · Job-site wiring
Serious$0$0Dec 12, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(f)(6)

(6) Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent and continuous.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(j)(1)(i)

(j) Equipment for general use—(1) Lighting fixtures, lampholders, lamps, and receptacles—(i) Live parts. Fixtures, lampholders, lamps, rosettes, and receptacles shall have no live parts normally exposed to employee contact. However, rosettes and cleat-type lampholders and receptacles located at least 8 feet (2.44 m) above the floor may have exposed parts.