OSHA SearchOSHA records by employer

C Barrera Quality Services Corp.: OSHA inspections and violations

Port Saint Lucie, Florida · Masonry Contractors · NAICS 238140

3inspections
9citation items
$10,276current penalties
Jan 26, 2023last inspection

OSHA has inspected C Barrera Quality Services Corp. 3 times in Florida since 2017.

The latest one began on Jan 26, 2023 as a planned inspection, in Port Saint Lucie.

Those inspections ended with 9 citation items: 9 serious.

Penalties were first proposed at $15,649 and now stand at $10,276, 34% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 5 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and C Barrera Quality Services Corp. averages $3,425 (3 cited inspections).

C Barrera Quality Services Corp.: OSHA citation items per year, 2017 to 2023
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

326employers cited

6 of them in the same industry

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch C Barrera Quality Services Corp. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346461163 OPENED JAN 26, 2023Closed

Planned · Partial · Safety · 5 employees at the site · Closed Jun 13, 2023

1200 Gatlin Boulevard, Port Saint Lucie, FL 34953 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Serious$2,679$1,607Apr 20, 2023Final
Citation 1, item 2a
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$2,679$1,607Apr 20, 2023Final
Citation 1, item 2b
29 CFR 1926.451(c)(2)(ii) · Scaffolds, general requirements
Serious$0$0Apr 20, 2023Final
Citation 1, item 3
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$2,679$1,607Apr 20, 2023Final
Citation 1, item 4
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$2,679$1,607Apr 20, 2023Final

Inspection 343050001 OPENED MAR 29, 2018Closed

Planned · Partial · Safety · 3 employees at the site · Closed Feb 3, 2025

10513 Sw Meeting Street, Port Saint Lucie, FL 34984 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$2,217$2,217Apr 19, 2018Final
Citation 1, item 1b
29 CFR 1926.454(a) · Scaffold training
Serious$0$0Apr 19, 2018Final

Inspection 342032430 OPENED JAN 18, 2017Closed

Planned · Partial · Safety · 2 employees at the site · Closed Oct 23, 2018

2014 10th Avenue, Vero Beach, FL 32960 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$2,716$1,630Mar 27, 2017Final
Citation 1, item 1b
29 CFR 1926.454(a) · Scaffold training
Serious$0$0Mar 27, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)(i)

(i) Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space between the platform and the uprights is no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary (for example, to fit around uprights when side brackets are used to extend the width of the platform).

29 CFR 1926.451(c)(2)

(2) Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.

29 CFR 1926.451(c)(2)(ii)

(ii) Unstable objects shall not be used to support scaffolds or platform units.

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.454 · Scaffold training

Other masonry contractors employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.