OSHA SearchOSHA records by employer

C - S Masonry Restoration LLC: OSHA inspections and violations

South Bend, Indiana · Masonry Contractors · NAICS 238140

1inspections
5citation items
$2,074current penalties
Mar 22, 2018last inspection

OSHA has inspected C - S Masonry Restoration LLC once in Indiana.

The inspection began on Mar 22, 2018 on a referral, in South Bend.

That inspection ended with 5 citation items: 4 serious and 1 other-than-serious.

Penalties were first proposed at $5,550 and now stand at $2,074, 63% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 4 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and C - S Masonry Restoration LLC averages $2,074 (1 cited inspection).

C - S Masonry Restoration LLC: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

Indiana · latest 90 days of OSHA records

79employers cited

Get notified the morning OSHA posts each new citation in Indiana: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Indiana

Checking a subcontractor, a client or your own company? Watch C - S Masonry Restoration LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343062915 OPENED MAR 22, 2018Closed

Referral · Partial · Safety · 8 employees at the site · Closed Jun 13, 2018

305 W North Shore Dr., South Bend, IN 46617 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2
29 CFR 1926.451(a)(1) · Scaffolds, general requirements
Other-than-serious$1,500$100Apr 19, 2018Final
Citation 1, item 3
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$1,500$731Apr 19, 2018Final
Citation 1, item 4
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$450$220Apr 19, 2018Final
Citation 1, item 5
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$1,500$731Apr 19, 2018Final
Citation 1, item 6
29 CFR 1926.452(c)(2) · Rules for each type of scaffold
Serious$600$292Apr 19, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(a)(1)

(a) Capacity. (1) Except as provided in paragraphs (a)(2), (a)(3), (a)(4), (a)(5) and (g) of this section, each scaffold and scaffold component shall be capable of supporting, without failure, its own weight and at least 4 times the maximum intended load applied or transmitted to it.

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(f)(7)

(7) Scaffolds shall be erected, moved, dismantled, or altered only under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration. Such activities shall be performed only by experienced and trained employees selected for such work by the competent person.

29 CFR 1926.452 · Rules for each type of scaffold

Other masonry contractors employers in Indiana

Alert subscribers get notified of each newly cited employer in Indiana the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.