C.W. Brinkley Inc.: OSHA inspections and violations
Suffolk, Virginia · Industrial Building Construction · NAICS 236210
12inspections
17citation items
$4,662current penalties
Apr 29, 2021last inspection
C.W. Brinkley Inc. has 12 OSHA inspections on record in Virginia, the first in 1996.
OSHA's last visit started on Apr 29, 2021 as a planned inspection, in Suffolk.
Across those inspections OSHA issued 17 citation items: 11 serious and 6 other-than-serious.
OSHA proposed $5,825 in penalties. After settlements and reviews the total is $4,662, down 20%.
Most often, OSHA cited 1926.651, excavations (3 items).
For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. C.W. Brinkley Inc. averages $1,800 over 1 cited inspection in that time.
C.W. Brinkley Inc. also files yearly injury logs with OSHA, summarized below.
Citation items per year, by inspection date.
Virginia · latest 90 days of OSHA records
246employers cited
Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2024, the Suffolk site logged 0 recordable injuries or illnesses among about 14 workers: 0.0 per 100 full-time workers, against a median of 0.6 for its industry.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
C.W. Brinkley, Inc.
Suffolk · 2024
14
0
0
0.0
0.6
Included with any plan: 8 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.
(ii) Ground-fault circuit interrupters. All 120-volt, single-phase, 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, shall have approved ground-fault circuit interrupters for personnel protection. Receptacles on a two-wire, single-phase portable or vehicle-mounted generator rated not more than 5kW, where the circuit conductors of the generator are insulated from the generator frame and all other grounded surfaces, need not be protected with ground-fault circuit interrupters.
(C) Receptacles shall be of the grounding type. Unless installed in a complete metallic raceway, each branch circuit shall contain a separate equipment grounding conductor, and all receptacles shall be electrically connected to the grounding conductor. Receptacles for uses other than temporary lighting shall not be installed on branch circuits which supply temporary lighting. Receptacles shall not be connected to the same ungrounded conductor of multiwire circuits which supply temporary lighting.
29 CFR 1926.405(a)(2)(ii)(f)
(F) Temporary lights shall not be suspended by their electric cords unless cords and lights are designed for this means of suspension.
Alert subscribers get notified of each newly cited employer in Virginia the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.