Cable System Installations: OSHA inspections and violations

Madison, Mississippi · Power and Communication Line and Related Structures Construction · NAICS 237130

1inspections
3citation items
$3,875current penalties
Mar 16, 2015last inspection

OSHA has inspected Cable System Installations once in Mississippi.

The inspection began on Mar 16, 2015 as a planned inspection, in Madison.

That inspection ended with 3 citation items: 3 serious.

Penalties were first proposed at $4,488 and now stand at $3,875, 14% lower after settlements or reviews.

Excavations comes up most often in these citations: 2 items under 1926.651.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,078, and Cable System Installations averages $3,875 (1 cited inspection).

Cable System Installations: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Want to know if OSHA cites Cable System Installations again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 340477835 OPENED MAR 16, 2015Closed

Planned · Partial · Safety · 4 employees at the site · Closed Jul 8, 2015

257 Grandview Drive, Madison, MS 39110 · Power and Communication Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.651(c)(2) · Excavations
Serious$2,244$1,445May 28, 2015Final
Citation 1, item 2a
29 CFR 1926.651(j)(2) · Excavations
Serious$2,244$1,215May 28, 2015Final
Citation 1, item 3b
29 CFR 1926.652(a)(1)(ii) · Trench protection
Serious$0$1,215May 28, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.651 · Excavations

29 CFR 1926.651(c)(2)

(2) Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees.

29 CFR 1926.651(j)(2)

(2) Employees shall be protected from excavated or other materials or equipment that could pose a hazard by falling or rolling into excavations. Protection shall be provided by placing and keeping such materials or equipment at least 2 feet (.61 m) from the edge of excavations, or by the use of retaining devices that are sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary.

29 CFR 1926.652 · Trench protection

29 CFR 1926.652(a)(1)(ii)

(ii) Excavations are less than 5 feet (1.52m) in depth and examination of the ground by a competent person provides no indication of a potential cave-in.