Inspection 343885927 OPENED MAR 27, 2019Closed
99 North St, Caledonia, NY 14423 · Elementary and Secondary Schools · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
OSHA has inspected Caledonia-Mumford CSD Elementary School 2 times in New York since 2018.
The latest one began on Mar 27, 2019 to follow up on an earlier case, in Caledonia.
Those inspections ended with 10 citation items: 10 serious.
None of the citations carried a penalty.
Electrical equipment, general requirements comes up most often in these citations: 5 items under 1910.303.
How that compares: the median penalty per cited inspection for education employers since 2015 is $0, and Caledonia-Mumford CSD Elementary School averages $0 (1 cited inspection).
New York · latest 90 days of OSHA records
360employers cited
3 of them in the same industry
Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in New York
Checking a subcontractor, a client or your own company? Watch Caledonia-Mumford CSD Elementary School and get notified the morning OSHA posts a new citation for it.
Watch this company99 North St, Caledonia, NY 14423 · Elementary and Secondary Schools · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
99 North St, Caledonia, NY 14423 · Elementary and Secondary Schools · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.37(b)(2) · Exit routes |
Serious | $0 | $0 | Feb 5, 2019 | Final |
| Citation 1, item 2 29 CFR 1910.213(d)(1) · Woodworking machinery |
Serious | $0 | $0 | Feb 5, 2019 | Final |
| Citation 1, item 3 29 CFR 1910.215(a)(1) · Grinders and abrasive wheels |
Serious | $0 | $0 | Feb 5, 2019 | Final |
| Citation 1, item 4 29 CFR 1910.303(b)(2) · Electrical equipment, general requirements |
Serious | $0 | $0 | Feb 5, 2019 | Final |
| Citation 1, item 5 29 CFR 1910.303(b)(7)(i) · Electrical equipment, general requirements |
Serious | $0 | $0 | Feb 5, 2019 | Final |
| Citation 1, item 6 29 CFR 1910.303(b)(7)(iv) · Electrical equipment, general requirements |
Serious | $0 | $0 | Feb 5, 2019 | Final |
| Citation 1, item 7 29 CFR 1910.303(f)(2) · Electrical equipment, general requirements |
Serious | $0 | $0 | Feb 5, 2019 | Final |
| Citation 1, item 8 29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements |
Serious | $0 | $0 | Feb 5, 2019 | Final |
| Citation 1, item 9 29 CFR 1910.305(b)(2)(i) · Electrical wiring methods |
Serious | $0 | $0 | Feb 5, 2019 | Final |
| Citation 1, item 10 29 CFR 1910.305(d)(2) · Electrical wiring methods |
Serious | $0 | $0 | Feb 5, 2019 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.213(d)(1)
(d) Hand-fed crosscut table saws. (1) Each circular crosscut table saw shall be guarded by a hood which shall meet all the requirements of paragraph (c)(1) of this section for hoods for circular ripsaws.
29 CFR 1910.215(a)(1)
(a) General requirements—(1) Machine guarding. Abrasive wheels shall be used only on machines provided with safety guards as defined in the following paragraphs of this section, except:
29 CFR 1910.303(b)(2)
(2) Installation and use. Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling.