OSHA SearchOSHA records by employer

California Pacific Technical Services, LLC: OSHA inspections and violations

Santa Rita, Guam · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

8inspections
7citation items
$5,274current penalties
Oct 16, 2023last inspection

OSHA has inspected California Pacific Technical Services, LLC 8 times in Guam since 2005.

The latest one began on Oct 16, 2023 as a planned inspection, in Mangilao.

Those inspections ended with 7 citation items: 7 other-than-serious.

Penalties were first proposed at $12,246 and now stand at $5,274, 57% lower after settlements or reviews.

Job-site wiring comes up most often in these citations: 2 items under 1926.405.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and California Pacific Technical Services, LLC averages $2,637 (2 cited inspections).

California Pacific Technical Services, LLC also files yearly injury logs with OSHA, summarized below.

It reported 1 severe injury to OSHA since 2015.

California Pacific Technical Services, LLC: OSHA citation items per year, 2005 to 2023
Citation items per year, by inspection date.

Guam · latest 90 days of OSHA records

6employers cited

Get notified the morning OSHA posts each new citation in Guam: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Guam

Checking a subcontractor, a client or your own company? Watch California Pacific Technical Services, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347045734 OPENED OCT 16, 2023Closed

Planned · Partial · Safety · 8 employees at the site · Closed Nov 30, 2023

Nearby To 148 Degracia Lane, Mangilao, GU 96913 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Other-than-serious$7,534$5,274Nov 7, 2023Final

Inspection 343151098 OPENED MAY 8, 2018Closed

Planned · Complete · Safety · 25 employees at the site · Closed Aug 27, 2018

P240 Mwss Facilities At North Ramp, Aafb, Yigo, GU 96929 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites
Other-than-serious$4,712$0Aug 2, 2018Final
Citation 1, item 2
29 CFR 1926.405(a)(2)(ii)(i) · Job-site wiring
Other-than-serious$0$0Aug 2, 2018Final

Inspection 340602101 OPENED APR 9, 2015Closed

Unprogrammed other · Complete · Safety · 45 employees at the site · Closed Apr 16, 2015

Dusit Thani Hotel, Tamuning, GU 96913 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 336969381 OPENED OCT 17, 2012Closed

Planned · Complete · Safety · 50 employees at the site · Closed Jan 28, 2013

Naval Base Guam Across Chapel, Santa Rita, GU 96915 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 2, item 1
29 CFR 1926.150(c)(1)(viii) · Fire protection
Other-than-serious$0$0Dec 14, 2012Final

Inspection 312495740 OPENED OCT 23, 2008Closed

Planned · Complete · Safety · 5 employees at the site · Closed Feb 11, 2009

Camp Covington, Santa Rita, GU 96915 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.21(b)(2) · Construction safety training
Other-than-serious$0$0Dec 30, 2008Closed

Inspection 309980944 OPENED MAY 16, 2006Closed

Unprogrammed other · Complete · Safety · 4 employees at the site · Closed Aug 15, 2006

Rt. 24a Fatima St., Dededo, GU 96929 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.51(a)(4) · Sanitation
Other-than-serious$0$0Jul 12, 2006Closed

Inspection 309980753 OPENED MAY 9, 2006Closed

Planned · Complete · Safety · 30 employees at the site · Closed Oct 3, 2006

Guam Telephone Authority, Barrigada, GU 96913 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1b
29 CFR 1926.405(g)(2)(iv) · Job-site wiring
Other-than-serious$0$0Aug 9, 2006Closed

Inspection 308734854 OPENED APR 13, 2005Closed

Planned · Complete · Safety · 10 employees at the site · Closed Apr 13, 2005

Camp Covington, Santa Rita, GU 96915 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Tamuning site logged 3 recordable injuries or illnesses among about 156 workers: 2.0 per 100 full-time workers, against a median of 1.8 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
California Pacific Technical Services, LLC
Tamuning · 2025
156 302.01.8

Included with any plan: 5 more yearly logs from these sites, back to 2017, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Jan 12, 2024, Dededo: Hospitalization · closed trauma involving internal organs, major blood vessels · other digestive structures n.e.c.

While conducting an insurance claim survey, an employee was inspecting AC units on a terrace floor with silicone coating that was wet due to rain and included some algae. The employee completed the survey and was leaving the site when he slipped and fell on the floor, landing on the left side of his ribcage. The employee suffered pain that required hospitalization, potentially due to spleen hematoma.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.150 · Fire protection

29 CFR 1926.150(c)(1)(viii)

(viii) Portable fire extinguishers shall be inspected periodically and maintained in accordance with Maintenance and Use of Portable Fire Extinguishers, NFPA No. 10A-1970.

29 CFR 1926.21 · Construction safety training

29 CFR 1926.21(b)(2)

(2) The employer shall instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(ii)

(ii) Ground-fault circuit interrupters. All 120-volt, single-phase, 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, shall have approved ground-fault circuit interrupters for personnel protection. Receptacles on a two-wire, single-phase portable or vehicle-mounted generator rated not more than 5kW, where the circuit conductors of the generator are insulated from the generator frame and all other grounded surfaces, need not be protected with ground-fault circuit interrupters.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.51 · Sanitation

Other electrical contractors and other wiring installation contractors employers in Guam

Alert subscribers get notified of each newly cited employer in Guam the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.