OSHA SearchOSHA records by employer

Calverthealth Medical Center, Inc.: OSHA inspections and violations

Prince Frederick, Maryland · General Medical and Surgical Hospitals · NAICS 622110

2inspections
6citation items
$3,650current penalties
Nov 23, 2021last inspection

Since 2019, OSHA inspectors have visited Calverthealth Medical Center, Inc. in Maryland 2 times.

The most recent inspection opened on Nov 23, 2021 after an accident, in Prince Frederick.

In all, OSHA issued 6 citation items: 3 serious and 3 other-than-serious.

The penalties, $3,650 in total, stand where OSHA first set them.

The rule cited most here is 1910.147 (lockout/tagout), 5 times.

Among health care employers, the typical cited inspection since 2015 ends with a $1,050 penalty. Calverthealth Medical Center, Inc. averages $3,650 across 1 cited inspection.

Calverthealth Medical Center, Inc. also files yearly injury logs with OSHA, summarized below.

Calverthealth Medical Center, Inc.: OSHA citation items per year, 2019 to 2021
Citation items per year, by inspection date.

Maryland · latest 90 days of OSHA records

180employers cited

Get notified the morning OSHA posts each new citation in Maryland: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Maryland

Checking a subcontractor, a client or your own company? Watch Calverthealth Medical Center, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345652507 OPENED NOV 23, 2021Closed

Accident · Partial · Safety · 13 employees at the site · Closed Apr 14, 2022

100 Hospital Road, Prince Frederick, MD 20678 · General Medical and Surgical Hospitals · OSHA's record · Phone and website on Google Maps

Incident on Nov 20, 2021: Employee's hand is caught in pinch point, finger is amputate

At 5:00 a.m. on November 20, 2021, Employee #1 was working on a Trane Performance Climate Changer Air Handler machine located on the roof of a hospital. The machine was squealing, leading the employee to inspect the machine by manually turning the fan belt to determine if it was too tight. The machine had been turned off during this process. While wearing work gloves, Employee #1 reached inside the machine. The motion of the belt caused the employee's work gloves to be grabbed, pulling the hand into the pinch point between the machine belt and pulley, resulting in a traumatic amputation of the employee's left fifth (pinky) finger. The employee was hospitized for treatment.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$3,150$3,150Mar 15, 2022Final
Citation 1, item 1b
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Serious$0$0Mar 15, 2022Final
Citation 1, item 1c
29 CFR 1910.147(c)(7)(i)(b) · Lockout/tagout
Serious$0$0Mar 15, 2022Final
Citation 2, item 1
29 CFR 1904.39(a)(2) · Reporting deaths and severe injuries
Other-than-serious$500$500Mar 15, 2022Final
Citation 2, item 2
29 CFR 1910.147(c)(6)(ii) · Lockout/tagout
Other-than-serious$0$0Mar 15, 2022Final
Citation 2, item 3
29 CFR 1910.147(c)(7)(iv) · Lockout/tagout
Other-than-serious$0$0Mar 15, 2022Final

Inspection 344481239 OPENED NOV 27, 2019Closed

Accident · Partial · Safety · 1,000 employees at the site · Closed Jan 3, 2020

100 Hospital Road, Prince Frederick, MD 20678 · General Medical and Surgical Hospitals · OSHA's record · Phone and website on Google Maps

Incident on Nov 26, 2019: Employee breaks leg, is burned when sprayed with hot water

At 3:45 p.m. on November 26, 2019, an employee who worked in maintenance for a medical center was in the process of repairing a leak in the ceiling. The employee identified the leak in a variable control valve located above a drop ceiling over a nurse's station in the emergency room. The valve has an actuator above the valve body that allows hot water to flow through the piping and provide heat throughout the emergency room. The employee was standing on a 6-foot Werner stepladder 10 feet 6 inches above the floor in order to reach the valve that turns off the water. The valve was positioned on the copper piping before the variable control valve. As the employee attempted to remove the variable control valve, the ?-inch copper pipe on the other side of the water shutoff valve burst showering him with hot water. According to a coworker (Director of Plant Operations) the water was approximately 180 to 190 degrees Fahrenheit in the copper pipe. The coworker also stated that the copper pipe burst on a joint that was improperly soldered years ago. After being showered with the hot water, the employee attempted to descend the ladder but slipped while doing so and fell to the concrete floor below. The employee sustained second degree burns from his left fingertips up to his shoulder, on the right side of his chest, neck, face and ear. He also broke his right femur in the fall and was hospitalized.

No citations from this inspection.

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2022, the Prince Frederick site logged 62 recordable injuries or illnesses among about 1,065 workers: 6.5 per 100 full-time workers, against a median of 4.7 for its industry. Those cases cost 395 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
CalvertHealth Medical Center
Prince Frederick · 2022
1,065 62326.54.7

Included with any plan: 3 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.39 · Reporting deaths and severe injuries

29 CFR 1904.39(a)(2)

(2) Within twenty-four (24) hours after the in-patient hospitalization of one or more employees or an employee's amputation or an employee's loss of an eye, as a result of a work-related incident, you must report the in-patient hospitalization, amputation, or loss of an eye to OSHA.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(4)(i)

(4) Energy control procedure. (i) Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.

29 CFR 1910.147(c)(6)(i)

(6) Periodic inspection. (i) The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.

Other general medical and surgical hospitals employers in Maryland

Alert subscribers get notified of each newly cited employer in Maryland the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.