Crystal Lake, Illinois · Industrial and Commercial Fan and Blower and Air Purification Equipment Manufacturing · NAICS 333413
3inspections
5citation items
$21,900current penalties
Jan 29, 2025last inspection
Since 2016, OSHA inspectors have visited Camfil USA, Inc. in Illinois 3 times.
The most recent inspection opened on Jan 29, 2025 after a complaint, in Crystal Lake.
In all, OSHA issued 5 citation items: 5 serious.
The proposed penalties came to $40,935; today they stand at $21,900, 47% less.
The rule cited most here is 1910.147 (lockout/tagout), 5 times.
Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Camfil USA, Inc. averages $10,950 across 2 cited inspections.
Camfil USA, Inc. also files yearly injury logs with OSHA, summarized below.
It reported 2 severe injuries to OSHA since 2015.
Citation items per year, by inspection date.
Illinois · latest 90 days of OSHA records
428employers cited
Get notified the morning OSHA posts each new citation in Illinois: the employer, the site address, the rules broken and the penalty.
OSHA records show Camfil USA, Inc. at 4 sites in 4 states. Together they've had 10 inspections and $60,028 in current penalties.
We match records by employer name and industry, so these sites are likely the same company, not certainly. Franchises and subsidiaries can file under one name.
Included with any plan: the site-by-site record for all 4 sites, with repeat and willful violations and citations per year for the whole company. Already a subscriber? Sign in.
Complaint · Partial · Health · 121 employees at the site · Closed Mar 25, 2025
500 S. Main Street, Crystal Lake, IL 60014 · Industrial and Commercial Fan and Blower and Air Purification Equipment Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Inspection 345669089 OPENED DEC 2, 2021Closed
Referral · Partial · Safety · 115 employees at the site · Closed Aug 29, 2022
500 S. Main Street, Crystal Lake, IL 60014 · Industrial and Commercial Fan and Blower and Air Purification Equipment Manufacturing · OSHA's record · Phone and website on Google Maps
Incident on Nov 17, 2021: Employee amputates finger in roller
At 12:00 noon on November 17, 2021, an employee was operating a pleater machine when she went to assist a maintenance worker feed the media into the rollers to start production. While the maintenance worker was manually feeding the media into the pleater through rollers that were not running, the employee went to help and the rollers rotated backwards and caught her finger. The employee was hospitalized to treat an amputation of her finger.
Referral · Partial · Safety · 56 employees at the site · Closed Sep 20, 2016
500 S. Main Street, Crystal Lake, IL 60014 · Ventilation, Heating, Air-Conditioning, and Commercial Refrigeration Equipment Manufacturing · OSHA's record · Phone and website on Google Maps
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2025, the Crystal Lake site logged 4 recordable injuries or illnesses among about 116 workers: 2.9 per 100 full-time workers, against a median of 2.4 for its industry. Those cases cost 141 days away from work.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
Camfil USA - Crystal Lake Plant
Crystal Lake · 2025
116
4
1
2.9
2.4
Camfil USA, Inc.
Crystal Lake · 2020
76
4
1
3.7
2.4
Camfil Crystal Lake
Crystal Lake · 2019
66
2
0
2.9
2.4
Severe injury reports
Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 2 reports on file.
A changeover was being performed on a pleater, and an employee was helping feed media into the machine's rollers. A roller pinched the employee's fingers resulting in amputation of a finger. The machine was not locked out at the time.
May 24, 2016, Crystal Lake: Hospitalization · fractures and other injuries, n.e.c. · hand(s), except finger(s)
An employee was changing over the assembly station. After she changed out the pop-up plate, she restarted the machine. The machine failed to cycle properly and a piece became stuck. The employee's hand then became caught in the cycling device. She sustained several right-hand fractures and a severe laceration by her right thumb.
The rules behind these citations
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
(c) General—(1) Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, start up or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source, and rendered inoperative.
29 CFR 1910.147(c)(4)(i)
(4) Energy control procedure. (i) Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.
29 CFR 1910.147(c)(7)(i)
(7) Training and communication. (i) The employer shall provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees. The training shall include the following:
Other industrial and commercial fan and blower and air purification equipment manufacturing employers in Illinois
Alert subscribers get notified of each newly cited employer in Illinois the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.