Inspection 344286711 OPENED SEP 4, 2019Closed
550 Tollgate, Elgin, IL 60120 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Machesney Park, Illinois · Water and Sewer Line and Related Structures Construction · NAICS 237110
Campton Construction, Inc. has 3 OSHA inspections on record in Illinois, the first in 2013.
OSHA's last visit started on Sep 4, 2019 as a planned inspection, in Elgin.
Across those inspections OSHA issued 3 citation items: 1 serious and 2 other-than-serious.
OSHA proposed $3,803 in penalties. After settlements and reviews the total is $3,000, down 21%.
Most often, OSHA cited 1926.651, excavations (2 items).
For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Campton Construction, Inc. averages $3,000 over 1 cited inspection in that time.
Want to know if OSHA cites Campton Construction, Inc. again? Add it to a watchlist and we will email you the morning the citation shows up.
Watch this company550 Tollgate, Elgin, IL 60120 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
2200 Seminary Drive, Woodstock, IL 60098 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.652(a)(1) · Trench protection |
Serious | $3,492 | $3,000 | Oct 5, 2018 | Final |
| Citation 2, item 1 29 CFR 1926.651(c)(2) · Excavations |
Other-than-serious | $311 | $0 | Oct 5, 2018 | Final |
9899 Gregory St., Machesney Park, IL 61115 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.651(k)(1) · Excavations |
Other-than-serious | $0 | $0 | May 3, 2013 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.651(c)(2)
(2) Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees.
29 CFR 1926.651(k)(1)
(k) Inspections. (1) Daily inspections of excavations, the adjacent areas, and protective systems shall be made by a competent person for evidence of a situation that could result in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions. An inspection shall be conducted by the competent person prior to the start of work and as needed throughout the shift. Inspections shall also be made after every rainstorm or other hazard increasing occurrence. These inspections are only required when employee exposure can be reasonably anticipated.
29 CFR 1926.652(a)(1)
(a) Protection of employees in excavations. (1) Each employee in an excavation shall be protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section except when:
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.