OSHA SearchOSHA records by employer

Canandaigua City WWTP: OSHA inspections and violations

Canandaigua, New York · Sewage Treatment Facilities · NAICS 221320

15inspections
48citation items
$0current penalties
Mar 13, 2018last inspection

OSHA has inspected Canandaigua City WWTP 15 times in New York since 1989.

The latest one began on Mar 13, 2018 to follow up on an earlier case, in Canandaigua.

Those inspections ended with 48 citation items: 28 serious and 20 other-than-serious.

None of the citations carried a penalty.

Respiratory protection comes up most often in these citations: 6 items under 1910.134.

How that compares: the median penalty per cited inspection for utility employers since 2015 is $0, and Canandaigua City WWTP averages $0 (1 cited inspection).

Canandaigua City WWTP: OSHA citation items per year, 1989 to 2018
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

361employers cited

4 of them in the same industry

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch Canandaigua City WWTP and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343009262 OPENED MAR 13, 2018Closed

Follow-up · Complete · Health · Local government · 6 employees at the site · Closed Mar 13, 2018

183 Saltonstall St., Canandaigua, NY 14424 · Sewage Treatment Facilities · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 342789302 OPENED NOV 17, 2017Closed

Planned · Complete · Health · Local government · 6 employees at the site · Closed Mar 13, 2018

183 Saltonstall St., Canandaigua, NY 14424 · Sewage Treatment Facilities · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.132(e) · Personal protective equipment, general requirements
Serious$0$0Feb 8, 2018Final
Citation 1, item 2
29 CFR 1910.146(d)(4) · Permit-required confined spaces
Serious$0$0Feb 8, 2018Final
Citation 1, item 3
29 CFR 1910.146(f) · Permit-required confined spaces
Serious$0$0Feb 8, 2018Final
Citation 1, item 4
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$0$0Feb 8, 2018Final
Citation 1, item 5
29 CFR 1910.151(c) · First aid and eyewash
Serious$0$0Feb 8, 2018Final
Citation 1, item 6
29 CFR 1910.1200(f)(6)(ii) · Hazard communication
Serious$0$0Feb 8, 2018Final
Citation 2, item 1
29 CFR 1910.1200(g)(8) · Hazard communication
Other-than-serious$0$0Feb 8, 2018Final
Citation 2, item 2
29 CFR 1910.1200(h) · Hazard communication
Other-than-serious$0$0Feb 8, 2018Final

Inspection 312539141 OPENED MAR 13, 2009Closed

Follow-up · Partial · Safety · Local government · 10 employees at the site · Closed Mar 13, 2009

183 Saltonstall St, Canandaigua, NY 14424 · Sewage Treatment Facilities · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 312539109 OPENED DEC 23, 2008Closed

Monitoring · Partial · Safety · Local government · 10 employees at the site · Closed Dec 23, 2008

183 Saltonstall St, Canandaigua, NY 14424 · Sewage Treatment Facilities · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 311596001 OPENED OCT 9, 2008Closed

Planned · Complete · Safety · Local government · 7 employees at the site · Closed Mar 25, 2009

183 Saltonstall St, Canandaigua, NY 14424 · Sewage Treatment Facilities · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$0$0Nov 4, 2008Closed
Citation 1, item 2
29 CFR 1910.304(g)(5) · Grounding and circuit protection
Serious$0$0Nov 4, 2008Closed
Citation 1, item 3
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Serious$0$0Nov 4, 2008Closed
Citation 2, item 1
29 CFR 1910.157(e)(3) · Portable fire extinguishers
Other-than-serious$0$0Nov 4, 2008Closed

Inspection 302275730 OPENED OCT 30, 1998Closed

Follow-up · Partial · Safety · Local government · 7 employees at the site · Closed Oct 30, 1998

183 Saltonstall St, Canandaigua, NY 14424 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 301630364 OPENED MAY 14, 1998Closed

Planned · Complete · Safety · Local government · 7 employees at the site · Closed Oct 30, 1998

183 Saltonstall St, Canandaigua, NY 14424 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.151(c) · First aid and eyewash
Serious$0$0Jul 31, 1998Closed
Citation 1, item 2
29 CFR 1910.305(b)(2) · Electrical wiring methods
Serious$0$0Jul 31, 1998Closed
Citation 1, item 3
29 CFR 1910.305(g)(2)(ii) · Electrical wiring methods
Serious$0$0Jul 31, 1998Closed
Citation 1, item 4
29 CFR 1910.334(a)(2)(i) · Using electrical equipment
Serious$0$0Jul 31, 1998Closed
Citation 2, item 1
29 CFR 1910.23(a)(8) · Guarding floor and wall openings and holes
Other-than-serious$0$0Jul 31, 1998Closed
Citation 2, item 2
29 CFR 1910.146(c)(5)(ic) · Permit-required confined spaces
Other-than-serious$0$0Jul 31, 1998Closed
Citation 2, item 3
29 CFR 1910.147(c)(4)(ii) · Lockout/tagout
Other-than-serious$0$0Jul 31, 1998Closed
Citation 2, item 4
29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements
Other-than-serious$0$0Jul 31, 1998Closed

Inspection 115920381 OPENED NOV 18, 1993Closed

Follow-up · Partial · Health · Local government · 7 employees at the site · Closed Nov 18, 1993

183 Saltonstall St, Canandaigua, NY 14424 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

7 older inspections

Inspection 104950688 OPENED MAR 15, 1991Closed

Follow-up · Partial · Safety · Local government · 7 employees at the site · Closed Mar 15, 1991

183 Saltonstall St, Canandaigua, NY 14424 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 104945977 OPENED SEP 5, 1990Closed

Follow-up · Partial · Health · Local government · 7 employees at the site · Closed Sep 5, 1990

183 Saltonstall St, Canandaigua, NY 14424 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 104945696 OPENED AUG 10, 1990Closed

Follow-up · Partial · Safety · Local government · 7 employees at the site · Closed Aug 10, 1990

183 Saltonstall St, Canandaigua, NY 14424 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 104924295 OPENED OCT 12, 1989Closed

Follow-up · Partial · Safety · Local government · 7 employees at the site · Closed Oct 12, 1989

183 Saltonstall St, Canandaigua, NY 14424 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 104974969 OPENED OCT 12, 1989Closed

Monitoring · Partial · Safety · Local government · 7 employees at the site · Closed Oct 12, 1989

183 Saltonstall St, Canandaigua, NY 14424 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 104865977 OPENED JUL 17, 1989Closed

Planned · Complete · Health · Local government · 7 employees at the site · Closed Sep 5, 1990

183 Saltonstall St, Canandaigua, NY 14424 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$0$0Jan 19, 1990Closed
Citation 1, item 2
29 CFR 1910.101(b) · Compressed gases (general requirements)
Serious$0$0Jan 19, 1990Closed
Citation 1, item 3
29 CFR 1910.134(a)(2) · Respiratory protection
Serious$0$0Jan 19, 1990Closed
Citation 1, item 4
29 CFR 1910.134(b)(10) · Respiratory protection
Serious$0$0Jan 19, 1990Closed
Citation 1, item 5
29 CFR 1910.134(e)(3) · Respiratory protection
Serious$0$0Jan 19, 1990Closed
Citation 1, item 6
29 CFR 1910.134(e)(3)(i) · Respiratory protection
Serious$0$0Jan 19, 1990Closed
Citation 1, item 7
29 CFR 1910.134(f)(2)(ii) · Respiratory protection
Serious$0$0Jan 19, 1990Closed
Citation 1, item 8
29 CFR 1910.151(c) · First aid and eyewash
Serious$0$0Jan 19, 1990Closed
Citation 1, item 9
29 CFR 3A0001
Serious$0$0Jan 19, 1990Closed
Citation 2, item 1
29 CFR 1910.133(a)(1) · Eye and face protection
Other-than-serious$0$0Jan 19, 1990Closed
Citation 2, item 2
29 CFR 1910.252(d)(2)(vii) · Welding fire safety
Other-than-serious$0$0Jan 19, 1990Closed
Citation 2, item 3
29 CFR 1910.252(f)(2)(ii) · Welding fire safety
Other-than-serious$0$0Jan 19, 1990Closed

Inspection 104865399 OPENED JUN 15, 1989Closed

Planned · Complete · Safety · Local government · 7 employees at the site · Closed Aug 10, 1990

183 Saltonstall St, Canandaigua, NY 14424 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.106(d)(5)(i) · Flammable liquids
Serious$0$0Jul 11, 1989Closed
Citation 1, item 2
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Serious$0$0Jul 11, 1989Closed
Citation 1, item 3
29 CFR 1910.252(a)(2)(iib) · Welding fire safety
Serious$0$0Jul 11, 1989Closed
Citation 1, item 4
29 CFR 1910.252(a)(2)(ivc) · Welding fire safety
Serious$0$0Jul 11, 1989Closed
Citation 1, item 5
29 CFR 1910.303(b)(1)(iii) · Electrical equipment, general requirements
Serious$0$0Jul 11, 1989Closed
Citation 1, item 6
29 CFR 1910.305(b)(1) · Electrical wiring methods
Serious$0$0Jul 11, 1989Closed
Citation 2, item 1
29 CFR 1910.23(d)(1)(ii) · Guarding floor and wall openings and holes
Other-than-serious$0$0Jul 11, 1989Closed
Citation 2, item 2
29 CFR 1910.106(e)(9)(ii) · Flammable liquids
Other-than-serious$0$0Jul 11, 1989Closed
Citation 2, item 3
29 CFR 1910.134(b)(1) · Respiratory protection
Other-than-serious$0$0Jul 11, 1989Closed
Citation 2, item 4
29 CFR 1910.135 · Head protection
Other-than-serious$0$0Jul 11, 1989Closed
Citation 2, item 5
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Other-than-serious$0$0Jul 11, 1989Closed
Citation 2, item 6
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Other-than-serious$0$0Jul 11, 1989Closed
Citation 2, item 7
29 CFR 1910.304(e)(1)(iv) · Grounding and circuit protection
Other-than-serious$0$0Jul 11, 1989Closed
Citation 2, item 8
29 CFR 1910.304(f)(5)(vc) · Grounding and circuit protection
Other-than-serious$0$0Jul 11, 1989Closed
Citation 2, item 9
29 CFR 1910.1200(f)(4) · Hazard communication
Other-than-serious$0$0Jul 11, 1989Closed
Citation 2, item 10
29 CFR 8010003 A01
Other-than-serious$0$0Jul 11, 1989Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.101 · Compressed gases (general requirements)

29 CFR 1910.101(b)

(b) Compressed gases. The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks shall be in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in § 1910.6.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(5)(i)

(5) Storage inside building—(i) Egress. Flammable liquids, including stock for sale, shall not be stored so as to limit use of exits, stairways, or areas normally used for the safe egress of people.

29 CFR 1910.106(e)(9)(ii)

(ii) Access. Adequate aisles shall be maintained for unobstructed movement of personnel and so that fire protection equipment can be brought to bear on any part of flammable liquid storage, use, or any unit physical operation.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.133 · Eye and face protection

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.135 · Head protection

29 CFR 1910.146 · Permit-required confined spaces

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.252 · Welding fire safety

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.334 · Using electrical equipment

29 CFR 1910.94 · Ventilation

Other sewage treatment facilities employers in New York

Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.