Inspection 343009262 OPENED MAR 13, 2018Closed
183 Saltonstall St., Canandaigua, NY 14424 · Sewage Treatment Facilities · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Canandaigua, New York · Sewage Treatment Facilities · NAICS 221320
OSHA has inspected Canandaigua City WWTP 15 times in New York since 1989.
The latest one began on Mar 13, 2018 to follow up on an earlier case, in Canandaigua.
Those inspections ended with 48 citation items: 28 serious and 20 other-than-serious.
None of the citations carried a penalty.
Respiratory protection comes up most often in these citations: 6 items under 1910.134.
How that compares: the median penalty per cited inspection for utility employers since 2015 is $0, and Canandaigua City WWTP averages $0 (1 cited inspection).
New York · latest 90 days of OSHA records
361employers cited
4 of them in the same industry
Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in New York
Checking a subcontractor, a client or your own company? Watch Canandaigua City WWTP and get notified the morning OSHA posts a new citation for it.
Watch this company183 Saltonstall St., Canandaigua, NY 14424 · Sewage Treatment Facilities · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
183 Saltonstall St., Canandaigua, NY 14424 · Sewage Treatment Facilities · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.132(e) · Personal protective equipment, general requirements |
Serious | $0 | $0 | Feb 8, 2018 | Final |
| Citation 1, item 2 29 CFR 1910.146(d)(4) · Permit-required confined spaces |
Serious | $0 | $0 | Feb 8, 2018 | Final |
| Citation 1, item 3 29 CFR 1910.146(f) · Permit-required confined spaces |
Serious | $0 | $0 | Feb 8, 2018 | Final |
| Citation 1, item 4 29 CFR 1910.147(c)(4)(i) · Lockout/tagout |
Serious | $0 | $0 | Feb 8, 2018 | Final |
| Citation 1, item 5 29 CFR 1910.151(c) · First aid and eyewash |
Serious | $0 | $0 | Feb 8, 2018 | Final |
| Citation 1, item 6 29 CFR 1910.1200(f)(6)(ii) · Hazard communication |
Serious | $0 | $0 | Feb 8, 2018 | Final |
| Citation 2, item 1 29 CFR 1910.1200(g)(8) · Hazard communication |
Other-than-serious | $0 | $0 | Feb 8, 2018 | Final |
| Citation 2, item 2 29 CFR 1910.1200(h) · Hazard communication |
Other-than-serious | $0 | $0 | Feb 8, 2018 | Final |
183 Saltonstall St, Canandaigua, NY 14424 · Sewage Treatment Facilities · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
183 Saltonstall St, Canandaigua, NY 14424 · Sewage Treatment Facilities · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
183 Saltonstall St, Canandaigua, NY 14424 · Sewage Treatment Facilities · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.303(b)(2) · Electrical equipment, general requirements |
Serious | $0 | $0 | Nov 4, 2008 | Closed |
| Citation 1, item 2 29 CFR 1910.304(g)(5) · Grounding and circuit protection |
Serious | $0 | $0 | Nov 4, 2008 | Closed |
| Citation 1, item 3 29 CFR 1910.305(b)(2)(i) · Electrical wiring methods |
Serious | $0 | $0 | Nov 4, 2008 | Closed |
| Citation 2, item 1 29 CFR 1910.157(e)(3) · Portable fire extinguishers |
Other-than-serious | $0 | $0 | Nov 4, 2008 | Closed |
183 Saltonstall St, Canandaigua, NY 14424 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
183 Saltonstall St, Canandaigua, NY 14424 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.151(c) · First aid and eyewash |
Serious | $0 | $0 | Jul 31, 1998 | Closed |
| Citation 1, item 2 29 CFR 1910.305(b)(2) · Electrical wiring methods |
Serious | $0 | $0 | Jul 31, 1998 | Closed |
| Citation 1, item 3 29 CFR 1910.305(g)(2)(ii) · Electrical wiring methods |
Serious | $0 | $0 | Jul 31, 1998 | Closed |
| Citation 1, item 4 29 CFR 1910.334(a)(2)(i) · Using electrical equipment |
Serious | $0 | $0 | Jul 31, 1998 | Closed |
| Citation 2, item 1 29 CFR 1910.23(a)(8) · Guarding floor and wall openings and holes |
Other-than-serious | $0 | $0 | Jul 31, 1998 | Closed |
| Citation 2, item 2 29 CFR 1910.146(c)(5)(ic) · Permit-required confined spaces |
Other-than-serious | $0 | $0 | Jul 31, 1998 | Closed |
| Citation 2, item 3 29 CFR 1910.147(c)(4)(ii) · Lockout/tagout |
Other-than-serious | $0 | $0 | Jul 31, 1998 | Closed |
| Citation 2, item 4 29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Jul 31, 1998 | Closed |
183 Saltonstall St, Canandaigua, NY 14424 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
183 Saltonstall St, Canandaigua, NY 14424 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
183 Saltonstall St, Canandaigua, NY 14424 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
183 Saltonstall St, Canandaigua, NY 14424 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
183 Saltonstall St, Canandaigua, NY 14424 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
183 Saltonstall St, Canandaigua, NY 14424 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
183 Saltonstall St, Canandaigua, NY 14424 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.94(a)(5)(iib) · Ventilation |
Serious | $0 | $0 | Jan 19, 1990 | Closed |
| Citation 1, item 2 29 CFR 1910.101(b) · Compressed gases (general requirements) |
Serious | $0 | $0 | Jan 19, 1990 | Closed |
| Citation 1, item 3 29 CFR 1910.134(a)(2) · Respiratory protection |
Serious | $0 | $0 | Jan 19, 1990 | Closed |
| Citation 1, item 4 29 CFR 1910.134(b)(10) · Respiratory protection |
Serious | $0 | $0 | Jan 19, 1990 | Closed |
| Citation 1, item 5 29 CFR 1910.134(e)(3) · Respiratory protection |
Serious | $0 | $0 | Jan 19, 1990 | Closed |
| Citation 1, item 6 29 CFR 1910.134(e)(3)(i) · Respiratory protection |
Serious | $0 | $0 | Jan 19, 1990 | Closed |
| Citation 1, item 7 29 CFR 1910.134(f)(2)(ii) · Respiratory protection |
Serious | $0 | $0 | Jan 19, 1990 | Closed |
| Citation 1, item 8 29 CFR 1910.151(c) · First aid and eyewash |
Serious | $0 | $0 | Jan 19, 1990 | Closed |
| Citation 1, item 9 29 CFR 3A0001 |
Serious | $0 | $0 | Jan 19, 1990 | Closed |
| Citation 2, item 1 29 CFR 1910.133(a)(1) · Eye and face protection |
Other-than-serious | $0 | $0 | Jan 19, 1990 | Closed |
| Citation 2, item 2 29 CFR 1910.252(d)(2)(vii) · Welding fire safety |
Other-than-serious | $0 | $0 | Jan 19, 1990 | Closed |
| Citation 2, item 3 29 CFR 1910.252(f)(2)(ii) · Welding fire safety |
Other-than-serious | $0 | $0 | Jan 19, 1990 | Closed |
183 Saltonstall St, Canandaigua, NY 14424 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.106(d)(5)(i) · Flammable liquids |
Serious | $0 | $0 | Jul 11, 1989 | Closed |
| Citation 1, item 2 29 CFR 1910.215(a)(4) · Grinders and abrasive wheels |
Serious | $0 | $0 | Jul 11, 1989 | Closed |
| Citation 1, item 3 29 CFR 1910.252(a)(2)(iib) · Welding fire safety |
Serious | $0 | $0 | Jul 11, 1989 | Closed |
| Citation 1, item 4 29 CFR 1910.252(a)(2)(ivc) · Welding fire safety |
Serious | $0 | $0 | Jul 11, 1989 | Closed |
| Citation 1, item 5 29 CFR 1910.303(b)(1)(iii) · Electrical equipment, general requirements |
Serious | $0 | $0 | Jul 11, 1989 | Closed |
| Citation 1, item 6 29 CFR 1910.305(b)(1) · Electrical wiring methods |
Serious | $0 | $0 | Jul 11, 1989 | Closed |
| Citation 2, item 1 29 CFR 1910.23(d)(1)(ii) · Guarding floor and wall openings and holes |
Other-than-serious | $0 | $0 | Jul 11, 1989 | Closed |
| Citation 2, item 2 29 CFR 1910.106(e)(9)(ii) · Flammable liquids |
Other-than-serious | $0 | $0 | Jul 11, 1989 | Closed |
| Citation 2, item 3 29 CFR 1910.134(b)(1) · Respiratory protection |
Other-than-serious | $0 | $0 | Jul 11, 1989 | Closed |
| Citation 2, item 4 29 CFR 1910.135 · Head protection |
Other-than-serious | $0 | $0 | Jul 11, 1989 | Closed |
| Citation 2, item 5 29 CFR 1910.157(c)(1) · Portable fire extinguishers |
Other-than-serious | $0 | $0 | Jul 11, 1989 | Closed |
| Citation 2, item 6 29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Jul 11, 1989 | Closed |
| Citation 2, item 7 29 CFR 1910.304(e)(1)(iv) · Grounding and circuit protection |
Other-than-serious | $0 | $0 | Jul 11, 1989 | Closed |
| Citation 2, item 8 29 CFR 1910.304(f)(5)(vc) · Grounding and circuit protection |
Other-than-serious | $0 | $0 | Jul 11, 1989 | Closed |
| Citation 2, item 9 29 CFR 1910.1200(f)(4) · Hazard communication |
Other-than-serious | $0 | $0 | Jul 11, 1989 | Closed |
| Citation 2, item 10 29 CFR 8010003 A01 |
Other-than-serious | $0 | $0 | Jul 11, 1989 | Closed |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.101(b)
(b) Compressed gases. The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks shall be in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in § 1910.6.
29 CFR 1910.106(d)(5)(i)
(5) Storage inside building—(i) Egress. Flammable liquids, including stock for sale, shall not be stored so as to limit use of exits, stairways, or areas normally used for the safe egress of people.
29 CFR 1910.106(e)(9)(ii)
(ii) Access. Adequate aisles shall be maintained for unobstructed movement of personnel and so that fire protection equipment can be brought to bear on any part of flammable liquid storage, use, or any unit physical operation.
Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.