Inspection 345905541 OPENED APR 19, 2022Closed
U.s. Route 45 And Cal Sag Canal, Palos Hills, IL 60465 · Painting and Wall Covering Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
OSHA has inspected Capital Industrial Coatings, LLC 4 times in Illinois since 2019.
The latest one began on Apr 19, 2022 as a planned inspection, in Palos Hills.
Those inspections ended with 8 citation items: 1 serious and 7 other-than-serious.
Penalties were first proposed at $22,732 and now stand at $13,774, 39% lower after settlements or reviews.
Lead in construction comes up most often in these citations: 2 items under 1926.62.
How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Capital Industrial Coatings, LLC averages $4,591 (3 cited inspections).
Illinois · latest 90 days of OSHA records
416employers cited
3 of them in the same industry
Get notified the morning OSHA posts each new citation in Illinois: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Illinois
Checking a subcontractor, a client or your own company? Watch Capital Industrial Coatings, LLC and get notified the morning OSHA posts a new citation for it.
Watch this companyU.s. Route 45 And Cal Sag Canal, Palos Hills, IL 60465 · Painting and Wall Covering Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
I-294 & I-90, Rosemont, IL 60018 · Painting and Wall Covering Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites |
Other-than-serious | $3,031 | $2,000 | Nov 4, 2019 | Final |
| Citation 1, item 2a 29 CFR 1926.451(g)(1) · Scaffolds, general requirements |
Serious | $3,789 | $2,774 | Nov 4, 2019 | Final |
| Citation 2, item 1 29 CFR 1926.502(d)(20) · Fall protection systems |
Other-than-serious | $0 | $0 | Nov 4, 2019 | Final |
| Citation 2, item 1b 29 CFR 1926.502(d)(1) · Fall protection systems |
Other-than-serious | $0 | $0 | Nov 4, 2019 | Final |
I-294 & I-90, Rosemont, IL 60018 · Painting and Wall Covering Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.134(h)(1)(i) · Respiratory protection |
Other-than-serious | $5,304 | $3,000 | Aug 9, 2019 | Final |
I-294 And Busse Rd. Illinois Tollway Bridge, Park Ridge, IL 60068 · Painting and Wall Covering Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.134(h)(1)(i) · Respiratory protection |
Other-than-serious | $5,304 | $3,000 | Aug 9, 2019 | Final |
| Citation 1, item 2a 29 CFR 1926.62(d)(1)(i) · Lead in construction |
Other-than-serious | $5,304 | $3,000 | Aug 9, 2019 | Final |
| Citation 1, item 2b 29 CFR 1926.62(d)(1)(iii) · Lead in construction |
Other-than-serious | $0 | $0 | Aug 9, 2019 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.134(h)(1)(i)
(i) Respirators issued for the exclusive use of an employee shall be cleaned and disinfected as often as necessary to be maintained in a sanitary condition;
29 CFR 1926.404(b)(1)(ii)
(ii) Ground-fault circuit interrupters. All 120-volt, single-phase, 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, shall have approved ground-fault circuit interrupters for personnel protection. Receptacles on a two-wire, single-phase portable or vehicle-mounted generator rated not more than 5kW, where the circuit conductors of the generator are insulated from the generator frame and all other grounded surfaces, need not be protected with ground-fault circuit interrupters.
29 CFR 1926.451(g)(1)
(g) Fall protection. (1) Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1) (i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers.
Alert subscribers get notified of each newly cited employer in Illinois the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.